The intent of this file is to document outstanding tasks for PyVVO. This document is still in a draft state.

Monitor topology changes, update model, kill optimization

This is effectively complete. One piece that did not get implemented but can be improved on later is waiting a certain amount of time to see if a switch "recloses" before killing the optimization. Currently, the optimization simply gets stopped when a switch changes state.

Summary

When the system topology changes, PyVVO's internal model needs to be updated, and the optimization may need re-triggered.

Details

The detection of topology changes can be done via an EquipmentManager that manages all switches in the system. Maybe the update_state method simply needs augmented to call some sort of callback when equipment changes. Since the individual EquipmentSinglePhase objects track their state and previous state, this should be pretty simple.

Once the EquipmentManager instance has reported a change, the "master" GLMManager should go through and update the switches in PyVVO's internal model of the system.

The solution here might be to create a higher level class which takes in all the EquipmentManagers (e.g. one for regulators, one for capacitors, one for switches, etc.) and the "master" GLMManager and keeps the model updated. This higher level class could also report when equipment changes state for use in managing the running optimization.

The final piece here is deciding when to kill the optimization and start again. Some faults will be cleared quickly, so there's no sense in immediately killing any running optimization. So really, this final piece is about tracking status changes over time, and if switches have not returned to their pre-event state, we need to re-trigger optimization.

Command Tracking

This is more than halfway complete - equipment commands that are sent out are now always verified to have taken hold. If they don't, the equipment is marked as inoperable. The remaining step would be to discover when the equipment is back in service. At present, the only feasible way to do this would be to repeatedly attempt to command it until it responds.

Summary

One event that the application needs to handle is unresponsive equipment. E.g., you send a tap position command to a regulator but it doesn't change it's position.

Details

There are a few pieces to this puzzle. First is, of course, detection. We need a mechanism for monitoring equipment that has recently had a command sent out. This could involve augmenting the EquipmentManager to be the one that actually sends out commands related to its equipment, and then watches for the change. What I don't like about this is the EquipmentManager then needs to be capable of querying the platform.

Perhaps a better approach would be to make some sort of class which has both a PlatformManager and an EquipmentManager as attributes, and ensures that those changes actually happen.

After detection has occurred, we need to flag the equipment as out of service. This could be as simple as adding some sort of flag to EquipmentSinglePhase tracking if the object is currently operable or not. The EquipmentSinglePhase class already has a "controllable" attribute, but I don't think we want to overload that one, as that currently indicates whether or not the equipment has a controller, not whether or not the control is working.

After detection and flagging, the optimization needs to be halted and re-triggered. The genetic algorithm will need to be modified so that it only attempts to control equipment which is "operable"/"working."

Inverters/General distributed generation (DG)

NOTE: This is complete for inverters, but additional work is needed to handle generators.

equipment.py needs to be extended so that it has a class for inverters/DG. Mainly, we need to be able to keep our internal model up to date with what's happening in the system with regards to P/Q output.

If done right, this should also be a good set up for future augmentation of PyVVO - specifically, the genetic algorithm (GA) should be able to manage DG set points, and later on we would want a solar forecast so that the GA uses expected upcoming weather rather than current weather.

Communication Outage

This is partly done. The SimOutRouter and EquipmentManager are now both logging warnings for missing measurements.

This can probably be handled similarly to command tracking/managing stuck equipment, but the detection is different. Presently, the SimOutRouter's _filter_output_by_mrid method throws an error if there is a missing measurement. Maybe instead of throwing an error it could warn in the log and then place None in the correct spot in the output. Then, the corresponding EquipmentManager could interpret receiving None as presently inoperable equipment.

Flow Control for Genetic Algorithm (GA)

Some of the other pieces here are inevitably going to involve stopping the GA. At present, the GA doesn't really have flow control. It'll need some methods of gracefully stopping - e.g. stop GridLAB-D models, drop all related tables (maybe, unless we drop the table up front, making dropping tables in cleanup unnecessary), etc.

Compare GA model results with real system

As a validation step, it would be useful to compare model outputs from the "baseline" individual in the genetic algorithm with the actual system output. For starters, it would be simplest to look at total feeder power and power factor. Eventually, it would be useful to compare EnergyConsumer voltage and/or power.

Finish Load Modeling With Historic Data

Title says it all.

Create Expected Behavior Section

Note what sort of logs we'll see for various events, etc.