Add bucket/session-level pump usage tracking #7

@HanClinto

Description

@HanClinto

Summary

Add future support for bucket-level or pump-session-level tracking/reporting, beyond the daily aggregate handle-stroke metrics planned in #6.

The motivation is that float-switch transitions are already a rough proxy for buckets or groups of buckets. Today boot_count / 2 is surprisingly useful as an approximate count of filled buckets/sessions, because the ESP32 wakes on float switch up/down events. With the new handle-stroke odometer, we can eventually make this much more informative: per-session dry strokes, flowing strokes, duration, and strokes-per-water-output behavior.

Why this matters

For predictive maintenance, daily totals are helpful but incomplete. We eventually want to know how handle effort relates to actual water production at a smaller granularity:

  • How many strokes were needed before water started flowing from dry/rested state?
  • How many strokes happened while water was flowing?
  • How many seconds did each water-flow interval last?
  • Were there repeated short stops between bucket changes where the pump was still primed?
  • Are strokes-per-minute or strokes-per-flow-duration trends changing over time?

This could help distinguish normal heavy use from changing pump performance.

Important caveat

Bucket/session-level reporting may generate a lot of extra data, especially at busy pumps. This should not be part of the first Counter 2 Click implementation unless the storage/reporting pipeline is ready for it.

Near-term #6 reporting should stay aggregate-oriented. This issue is for designing the later richer data model.

Possible future session model

A future firmware model could track each water-flow interval as a session-like record:

  • session start time
  • session end time
  • flow duration seconds
  • handle strokes before flow start, if pump was considered dry
  • handle strokes while water was flowing
  • dry/primed classification
  • maybe bucket/session sequence count for the report period

Short gaps between float-switch active periods should probably be merged or classified as the same primed pumping session if the water was off for less than a configurable drain interval.

Drain-time / priming rule

Add a configuration value such as:

  • WATERPAL_MIN_DRY_DRAIN_TIME_S

Default should be conservative, likely around 240 seconds until field testing says otherwise.

If water stops flowing for only a second or two while users swap buckets or workers, the pump is still partially primed. That short gap should not feed the dry-start metric. Only after the float switch has been inactive for at least WATERPAL_MIN_DRY_DRAIN_TIME_S should the next flow-start event be considered a true dry/rested start.

Acceptance criteria for a future implementation

  • Firmware can distinguish dry-start sessions from primed continuation sessions using a configurable minimum drain time.
  • Firmware can record per-session or per-bucket-ish metrics without losing daily aggregate metrics.
  • Reporting/storage format is designed to avoid runaway SMS/HTTP payload size.
  • Backend/app can display or summarize per-session data usefully.
  • Field testing validates the chosen drain-time threshold and whether short gaps should be merged or tracked separately.

Related