Skip to content

QR erroring out silently with exit code 0 if autophotflat is selected #17

@agopu

Description

@agopu

We've discovered another instance of the pipeline erroring out silently without producing output data and with exit code 0 -- this time when the user selected the autophotflat option.

Running the same job without that option helps produce output data, albeit without that correction.

Reference job on ODI-PPA: https://portal.odi.iu.edu/process/oldjob?jid=8897. Note that this option is not 'selected' by default on the portal but the user requested it; perhaps we should remove the option altogether, we will discuss this with Wilson, et al.

Additional information from Mike Young:

  • "It’s a secondary correction. It looks like the QR FITS output is created, then when the autophotflat is applied it deletes the original output but fails to write out the corrected version."
  • "Found this in the log when that option is turned on"
    2020-10-20 12:18:32,718 Process-2:23 20190510T205339.1 - OTA21.SCI WARNING Something went wrong with the sky-calculation: (0,)