Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathauto_switch.py
More file actions
179 lines (151 loc) · 7.86 KB
/
auto_switch.py
File metadata and controls
179 lines (151 loc) · 7.86 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
#!/usr/bin/env python3
import dbus
import logging
import os
import sys
from dbus.mainloop.glib import DBusGMainLoop
from gi.repository import GLib
#logging.basicConfig(level=logging.INFO)
logger = logging.getLogger()
for handler in logger.handlers[:]:
logger.removeHandler(handler)
formatter = logging.Formatter('%(asctime)s - %(name)s - %(levelname)s - %(message)s')
console_handler = logging.StreamHandler(sys.stdout)
console_handler.setFormatter(formatter)
logger.addHandler(console_handler)
logger.setLevel(logging.INFO) # Default to DEBUG for better visibility
# D-Bus service names and paths
SETTINGS_SERVICE_NAME = "com.victronenergy.settings"
SYSTEM_SERVICE = "com.victronenergy.system"
AC_ACTIVE_INPUT_SOURCE_PATH = "/Ac/ActiveIn/Source"
RELAY_PATH_BASE = "/Relay/"
CUSTOM_NAME_PATH_SUFFIX = "/CustomName"
STATE_PATH_SUFFIX = "/State"
BUS_ITEM_INTERFACE = "com.victronenergy.BusItem"
SETTINGS_RELAY_BASE_PATH = "/Settings/Relay"
TARGET_CUSTOM_NAMES = ["AC Water Heater", "AC WH"] # you can add/remove/change custom names here that the service will look for
MAX_RELAY_NUMBER_TO_CHECK = 10 # Adjust this if you expect more relays
class WaterHeaterController:
def __init__(self):
self.bus = dbus.SystemBus()
self.water_heater_relay_number = None
self.previous_ac_source = None
self.initial_state_set = False
self.relay_found = False # Flag to prevent repeated finding
self._ac_source_unavailable_warning_logged = False
# Find the water heater relay at startup, keep trying every 5 seconds
GLib.timeout_add_seconds(5, self._find_water_heater_relay) # Increased initial delay to 5 seconds
def _get_dbus_object(self, service_name, path):
try:
return self.bus.get_object(service_name, path)
except dbus.exceptions.DBusException as e:
# Removed error logging here to avoid log spam during startup if service isn't ready
return None
def _get_dbus_value(self, service_name, path):
obj = self._get_dbus_object(service_name, path)
if obj:
try:
interface = dbus.Interface(obj, BUS_ITEM_INTERFACE)
return interface.GetValue()
except dbus.exceptions.DBusException as e:
logging.error(f"Error getting value from {service_name}{path}: {e}")
return None
def _set_relay_state(self, relay_number, value):
if relay_number is not None:
path = f"{RELAY_PATH_BASE}{relay_number}{STATE_PATH_SUFFIX}"
obj = self._get_dbus_object(SYSTEM_SERVICE, path)
if obj:
try:
interface = dbus.Interface(obj, BUS_ITEM_INTERFACE)
interface.SetValue(dbus.Int32(value))
logging.info(f"Set {SYSTEM_SERVICE}{path} to {value} (Water Heater Relay)")
return True
except dbus.exceptions.DBusException as e:
logging.error(f"Error setting value for {SYSTEM_SERVICE}{path}: {e}")
return False
def _find_water_heater_relay(self):
if self.relay_found:
return False # Stop running once found
logging.info(f"Attempting to find water heater relay with custom names: {TARGET_CUSTOM_NAMES}")
for relay_number in range(MAX_RELAY_NUMBER_TO_CHECK):
custom_name_path = f"{SETTINGS_RELAY_BASE_PATH}/{relay_number}{CUSTOM_NAME_PATH_SUFFIX}"
custom_name = self._get_dbus_value(SETTINGS_SERVICE_NAME, custom_name_path)
if custom_name in TARGET_CUSTOM_NAMES:
self.water_heater_relay_number = relay_number
logging.info(f"Found Water Heater Relay: Number {relay_number}")
self.relay_found = True
# Set initial AC source and then start monitoring
GLib.timeout_add_seconds(1, self._initialize_monitoring)
return False # Stop further searching and scheduling this function
# If not found after checking all relays, schedule to try again
logging.info("Water heater relay not found yet. Will retry...")
return True # Keep running this timeout until found
def _initialize_monitoring(self):
if self.initial_state_set or self.water_heater_relay_number is None:
return False # Only run once if initial state is set or relay not found yet
source_value = self._get_dbus_value(SYSTEM_SERVICE, AC_ACTIVE_INPUT_SOURCE_PATH)
if source_value is not None:
# AC source is available, reset the warning flag if it was previously set
if self._ac_source_unavailable_warning_logged:
logging.info("AC input source is now available for initial state setting. Resetting warning flag.")
self._ac_source_unavailable_warning_logged = False
source_text = self._interpret_ac_source(source_value)
logging.info(f"Initial AC input source: {source_text}")
if source_text in ["Grid", "Shore"]:
self._set_relay_state(self.water_heater_relay_number, 1) # Turn on
else:
self._set_relay_state(self.water_heater_relay_number, 0) # Turn off
self.previous_ac_source = source_value
self.initial_state_set = True
# Now start the periodic monitoring
GLib.timeout_add_seconds(5, self._monitor_ac_input_source)
return False # Don't run again
else:
# AC input source not available, log warning only if not already logged
if not self._ac_source_unavailable_warning_logged:
logging.warning("AC input source not available for initial state setting. Retrying...")
self._ac_source_unavailable_warning_logged = True
return True # Try again if source is not available yet
def _monitor_ac_input_source(self):
if not self.initial_state_set or self.water_heater_relay_number is None:
return True # Wait until initial state is set and relay is found
source_value = self._get_dbus_value(SYSTEM_SERVICE, AC_ACTIVE_INPUT_SOURCE_PATH)
if source_value is not None:
# AC source is available, reset the warning flag if it was previously set
if self._ac_source_unavailable_warning_logged:
logging.info("AC input source is now available during monitoring. Resetting warning flag.")
self._ac_source_unavailable_warning_logged = False
if source_value != self.previous_ac_source:
source_text = self._interpret_ac_source(source_value)
logging.info(f"AC Input Source changed to: {source_text} (Value: {source_value})")
if source_text in ["Grid", "Shore"]:
self._set_relay_state(self.water_heater_relay_number, 1) # Turn on
else:
self._set_relay_state(self.water_heater_relay_number, 0) # Turn off
self.previous_ac_source = source_value
else: # source_value is None, meaning AC input source is unavailable
# Log warning only if not already logged
if not self._ac_source_unavailable_warning_logged:
logging.warning(f"Could not read AC input source during monitoring. Retrying...")
self._ac_source_unavailable_warning_logged = True
return True # Continue monitoring
def _interpret_ac_source(self, value):
if value == 0:
return "Unavailable"
elif value == 1:
return "Grid"
elif value == 2:
return "Generator"
elif value in [3, 4]:
return "Shore"
elif value == 240:
return "Inverting"
else:
return f"Unknown ({value})"
def main():
DBusGMainLoop(set_as_default=True)
WaterHeaterController()
mainloop = GLib.MainLoop()
mainloop.run()