Skip to content

2110-40 analysis is unable to identify ST 291 #151

@p5kilo

Description

@p5kilo

Hello,

I'm running a local instance of EBU-LIST in docker desktop and it seems unable to analyze the ancillary data packets in my 2110-40 streams. It correctly identifies payload IDs 0x51/0x01 (Film Codes in VANC space (RP215)) and 0x41/0x01 (Payload Identification, HANC space (S352)), but it identifies 0xE3 (Audio data in HANC space (HDTV) (ST 299-1)) incorrectly as an unidentifiable payload type, despite getting the line number and offset correct from the packet.

A 2110-40 plugin for wireshark has no problem identifying the packet as a ST 291 payload type:

ST 2110_40 Data
Extended Sequence Number: 0x0051
Length: 24
ANC_Count: 1
00.. .... = (F)ield: unspecified or progressive scan (0x0)
Packet 1: DID 0xe3, SDID 0x00: Audio data in HANC space (HDTV) (ST 299-1)
0... .... = (C) or Y: Y:Luma
.000 0000 1001 .... = Line_Number: 9
.... 0111 1000 1000 = Horizontal_Offset: 1928
0... .... = S: StreamNum not used
.000 0001 = StreamNum: 1
..11 1000 11.. .... = DID: 0xe3
.... 0000 0000 .... = SDID: 0x00: Audio data in HANC space (HDTV) (ST 299-1)
.... ..00 0010 11.. = Data_Count: 11
UDW Bytes: 2e 05 80 20 38 02 00 80 20 08 02 00 80 20 0b
Checksum Word: 0x2f6
[UDW Array: 05 00 03 00 00 00 00 00 00 00 00]

Payload_unknown

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type
    No fields configured for issues without a type.

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions