Module Configuration

The configuration of each module is stored in the directory $SHEM_HOME/modules/[module_name]. It can contain several files and folders, of which all but the image file are optional. For example, the configuration directory for the orchestrator (which uses the reserved module name "orchestrator") could look like this (file contents are shown in square brackets, with \n for newline characters):

$SHEM_HOME/modules/orchestrator/
|-- image  [quay.io/shem/shem-orchestrator]
|-- public_key  [cQyjQftwIlSGYvWjfDMzpr0B5/Lr/S8jDFfVW3hOBk0=]
|-- current_version  [0.0.4]
|-- blacklist  [0.0.2\n0.0.3]
|-- inputs  []
|-- module-config/
|-- storage/

The name of the directory is the name of the module. It must consist only of alphanumerical characters and the underscore character (a-z, A-Z, 0-9, _). Its maximum length is 100 characters.

The files and the directory have these meanings:

  • image: the container image (without version-architecture tag) that this module uses; several modules can use the same image, or even different versions of the same image
  • public_key: if this is supplied, automatic updates are enabled and checked against this key (see ./update-mechanism.md for details)
  • current_version: the version the orchestrator will use (except during updates); if left out, the orchestrator selects the newest locally available version and saves the version number into this file
  • blacklist: contains blacklisted version numbers, one per line
  • inputs: specifies which messages from other modules this module receives (see Message Routing)
  • module-config/: a directory for configuration files that is mounted read-only into the module's container
  • storage/: modules that are allowed to persist data will have this directory mounted into the container

The orchestrator re-reads a config file each time it needs the corresponding config value. Changes therefore become effective after a short time without any need to signal or restart the orchestrator.

Orchestrator additional options

These options can be set by creating a file named after the option in $SHEM_HOME/modules/orchestrator/:

  • UpdateCheckIntervalHours: Update check interval in hours (default: 22.15)
  • UpdateDelayMaxHours: Maximum update delay in hours for staggered updates across instances (default: 96.0)

Module Communication

Each module communicates with the orchestrator via its standard input (stdin), standard output (stdout) and standard error (stderr). Notifications including error messages are sent via stderr, messages containing values in a certain format are sent via stdout.

All messages are ASCII encoded and limited to the printable character set (0x20 to 0x7E) plus the newline character (0x0A). Numerical values are represented as text. These rules ensure that the messages are human-readable and that there are no ambiguities in how to parse the message. The orchestrator enforces message validity.

The Go library shemmsg (in the shemmsg/ directory) provides parsing, validation, and encoding of messages. It is the same code as used by the orchestrator and has been outsourced so that it can be used by other modules as well.

Notifications and Error Messages

These messages are sent via stderr. Each line (i.e., a string of ASCII characters ending with a newline symbol) is treated as a single message. Message length is limited to 1000 characters (not counting the newline symbol). It may start with a string like "<3>" or "<7>" to indicate the log level (see man 3 sd-daemon).

Messages of this type are not parsed by the orchestrator. Depending on logging config, they may be logged.

Parsed Messages

Parsed messages are sent and received via stdout and stdin. They have a type, which determines their format, and also a name of the variable whose value they contain. The first line consists of type and name, divided by a space character. Messages are divided by two or more consecutive newline characters (i.e., an empty line). You can therefore start and end each message sent with two newline characters. Here is an example of a valid message of type pointvalue that gives the current value of the variable net_power of the sending module:



pointvalue net_power
-802.10


Message length is limited to 10000 bytes (not counting newlines). The variable name consists of alphanumerical characters and the underscore character (a-z, A-Z, 0-9 and _). It must be at most 100 characters long. The orchestrator will expand the name to a fully qualified name in the form module_name.variable_name, where module_name is the name of the originating module. When a module sends a message, it leaves out its module name.

The message types and their descriptions follow.

Point Values

In messages of type pointvalue, the type/name line is followed by a single line containing a decimal number in the format (-)12345678.123. Numbers must therefore have an absolute value smaller than 100 million. Leading zeros and trailing zeros after the decimal point can be omitted, as well as the decimal point if only zeros would follow. The value may be missing, in which case it is represented by the string "missing".

Values for electric power should be given in kilowatts, and electric energy in kilowatt-hours.

Examples:

pointvalue net_power
-802.10


pointvalue total_energy
9371802

pointvalue irradiance
missing

The value always refers to the current point in time. Otherwise, a time series (see below) with a single value may be used.

Time Series

In messages of type timeseries, the type/name line is followed by a line containing the UTC timestamp of the first value in the format yyyy-mm-ddThh:mm. Each subsequent line contains a single value, following the same rules as for point values.

All time series use a fixed time step of 5 minutes. The minutes component of the timestamp must be a multiple of 5 (i.e., 00, 05, 10, …, 55). If a quantity changes more slowly (e.g., hourly energy prices), the value is simply repeated for each 5-minute interval. This fixed time step simplifies parsing and eliminates errors from inconsistent intervals.

For instantaneous measurements (e.g., meter readings) reported as a time series, the timestamp indicates when the measurement was taken. For values that represent a quantity over a duration (such as energy prices or power averages), time series are left-labeled. This means each value applies to the 5-minute interval beginning at its timestamp. For example, a value with timestamp 2025-12-06T08:00 applies to the interval from 08:00:00 up to but not including 08:05:00 UTC.

Example:


timeseries pv_forecast
2025-12-06T08:00
120.0
145.1
missing
140.5

Module Shutdown

The orchestrator closes stdin when it wants to shut down a module. Modules should therefore monitor the closing of stdin. If a module does not exit within a certain time after stdin is closed, the orchestrator will forcibly shut it down.

Module Malfunction Detection

The orchestrator will interpret a too large rate of messages or many malformed messages as a sign of module failure.

Message Routing

Modules cannot communicate directly with each other. All message routing is controlled by the orchestrator based on configuration files. This ensures that data flow between modules is determined by the user, not by the modules themselves.

Message Processing

When a module sends a parsed message (via stdout), the orchestrator:

  1. validates the format and parses the message,
  2. qualifies the variable name by prefixing it with the module name (e.g., net_power from the meter module becomes meter.net_power), and
  3. reconstructs and sends the message to all subscribing modules.

The orchestrator's parsing and re-emission ensures that all forwarded messages are in a consistent format and protects against malformed data.

The inputs File

A module's subscriptions are configured in the inputs file within its configuration directory. Each line specifies a pattern for messages the module wishes to receive. Empty lines and lines containing only whitespace are ignored.

The file supports two forms:

module_name.variable_name
module_name.variable_name localname

The first form subscribes to messages from module module_name for the value value_name. Both module_name and value_name may be the wildcard "*" to indicate that messages from all modules or for all values are to be forwarded. The pattern "*.*" is also valid (e.g., for data logging).

The second form supplies an alias localname for the variable. These messages are delivered with the name localname instead of module_name.variable_name. Wildcards are not allowed in this case.

If no messages are to be received, the input file can be either empty or missing. If several lines in a single inputs file match the same message, the module receives the message several times.

Example inputs file:

meter.net_power
optimizer.device_2_setpoint setpoint
*.temperature
gui.*

This module would receive:

  • meter.net_power (as meter.net_power)
  • optimizer.device_2_setpoint as setpoint
  • temperature values from all modules (under their fully qualified names)
  • all values from module gui (under their fully qualified names)