Skip to content

FVT1060:Invalid power cap value is set via IPMI. #3639

@yadlapati

Description

@yadlapati

Description

======================

Invalid power cap value is set via IPMI.

System details

=================

System : bonn008(service/0penBmc0)

BMC fw : fw1060.00-4.33-1060.2410.20240308a (NL1060_033)

Steps to re- create

======================

Step1 : Login to system

Step2: Executing the IPMI command to set the power cap value  600 and 500 , Min and Max value is 583 and 3982:

Value 600:

bash-4.2$ ipmitool -I lanplus -C 17 -N 3 -p 623 -U ipmi_admin -H bonn008.aus.stglabs.ibm.com dcmi power set_limit limit 600

Password:

    Current Limit State: Power Limit Active

    Exception actions:   Hard Power Off & Log Event to SEL

    Power Limit:         600 Watts

    Correction time:     0 milliseconds

    Sampling period:     0 seconds

Value 600 is set successfully

Step3:

Value 500:

bash-4.2$ ipmitool -I lanplus -C 17 -N 3 -p 623 -U ipmi_admin -H bonn008.aus.stglabs.ibm.com dcmi power set_limit limit 500

Password:

    Current Limit State: Power Limit Active

    Exception actions:   Hard Power Off & Log Event to SEL

    Power Limit:         500 Watts

    Correction time:     0 milliseconds

    Sampling period:     0 seconds

The Value 500 is below the minimum value ,but its taking the value has 556

Actual behaviour: Able to set a invalid value(below the minimum power cap value ) and with no error response for invalid value its able to set a random value.

Expected Behaviour: Need to get a error for setting a below minimum power cap value .

Metadata

Metadata

Assignees

No one assigned

    Labels

    ReadyForDevStories ready for development workbugSomething isn't working

    Type

    No type
    No fields configured for issues without a type.

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions