# Configuration file for the pCT preprocessing and calibration program
#Lines do not have to begin in the first column
#Spaces are optional, but the = sign is required
#key = value lines can also include comments after the value(space required)
#Blank lines are not allowed, at least for now(will cause a crash)
max_events = 0 # Set nonzero if you don't want to analyze all of the events
dEEFilter = 1 # dEE FILTER to be used always (will result in bad events returned with 5000+WEPL)
energy = 200 # Beam Energy used in this experiment. Should always be 200 for now.
normalize = 0 # HAS TO STAY 0 FOR NOW (an addition from Robert that results in massive deterioriation of the calib curves, it is not fully understood why)
fraction = 1 # Fraction of the input file to be read and processed
time = 0 # Set nonzero to specify a maximum time stamp to analyze, in seconds
user = no # Set to 'yes' only if you want to generate all of the monitoring histograms (takes quite a bit of extra time)
projection = -999. # Normally the correct value is taken from the run header, so don't use this
continuous = 0 # Difference between stepped and continuous scan is shown here
bins = 1 # Specify the number of files to split the data into
outputDir = . # Leave as '.' only if you want all the output to end up in the current directory
calib = pCTcalib.root # New root calibration file contains all the calibrations
log = NULL # Specify a path to the DAQ log file, continuous scans -> find the starting angle
angle = 0. # For a continuous scan, if this angle is zero, then the program will try to get it from the log file
thr0 = 1.0 # Don't change these calibration thresholds unless you really know what you are doing
thr1 = 1.0 # For calibration runs, these set the threshold values used and written out into the WEPL calibration file
thr2 = 1.0 # For preprocessing runs these will get overwritten by values obtained from the WEPL calibration file, if they are present there
thr3 = 1.0
thr4 = 1.0
pedrng0 = -500 # Lower limit of the pedestal range. The pedestal must be within this value up to the value plus 2000 ADC counts
pedrng1 = -500
pedrng2 = -1000
pedrng3 = -1000
pedrng4 = -1000
partType = He # Hydrogen or Helium ions
calibrate = 0 # Set to 1 to analyze the calibration phantom run files to generate the Wcalib.txt and TVcorr.txt calibration files
CalibCurve = 1 # Use either regular multistage calibration (0, default), or single stage with EvsRange (1) RangeVsE (2)
recalibrate = 1 # Normally 1 to make the program recalibrate gains by using protons that miss the phantom.
sizeright = 90 # Maximum radius of the phantom, needed in order to select undegraded protons for recalibration of gains
sizeleft = 90
wedgeoffset = -50.8 # Offset of the phantom from center , in the T direction, in mm (introduced for the HIT runs where it was -50.8)
study = NULL # Can be used to override automatic generation of the study name from the filename
MultiTrackReject = 0 # Per default this is false, if set to 1, any event with more than one possible track vector in either tracker will be rejected
CTOutput = 0 # Flag to indicate whether the root file should comprise the full output or a reduced version with the necessary variables for CT imaging
TpinOff1 = -1
TpinOff2 = -1
TpinOff3 = 1.218
TpinOff4 = 1.363
VpinOff1 = 0
VpinOff2 = 0
VpinOff3 = 0
VpinOff4 = 0
#maxFluence = 280 #Maximum fluence in part/mm^2 to normalize the intial fluence
#Last line of the file