Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathTRANS_CAP_README.m
More file actions
112 lines (97 loc) · 2.41 KB
/
TRANS_CAP_README.m
File metadata and controls
112 lines (97 loc) · 2.41 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
%% TRANSIENT CAPTURE README
% This is the readme document for the MATLAB Transient Capture Interface for ACQ400
% products from D-TACQ Solutions.
%
% An example run of transient capture is shown before delving into the
% constituent parts of the application. This detail should allow you to
% tweak the application or create your own custom interface.
%
% Click on the hyperlinks in this document to go to detailed views of the
% constituent functions. The highest level script,
% <trans_cap.html transient_commands.m>, is used to drive
% acquisition. The most detailed discussion of the interface to
% the card is given in <transient_commands.html transient_commands.m>.
%% Example Run
% * Define your UUT (Unit Under Test) as follows.
global UUT
% Without DNS
UUT = '10.12.196.103'; % IP address of YOUR product, this is just an example.
% With DNS
UUT = 'acq2006_014';
%%%
% * From here call the <trans_cap.html |trans_cap|> function with arguments. Arguments are detailed <trans_cap.html here>.
%
%%
% >> trans_cap('acq437',10000,0,16,'hard',128000)
% acq2006_014
%
% New sample rate = ACQ43X_SAMPLE_RATE 128000 Hz
%
% Gains :
% CH01= 10V CH02= 10V CH03= 10V CH04= 10V CH05= 10V CH06= 10V CH07= 10V CH08= 10V CH09= 10V CH10= 10V CH11= 10V CH12= 10V CH13= 10V CH14= 10V CH15= 10V CH16= 10V
%
% set.site 1 trg=1,0,1
% soft_transient 10000
% set_arm
%
% ...Running Transient Capture ...
%
% ...Transient Capture Complete...
%
% ...Pulling Channel Data from D-TACQ ACQ...
%
% 1
%
% 2
%
% 3
%
% 4
%
% 5
%
% 6
%
% 7
%
% 8
%
% 9
%
% 10
%
% 11
%
% 12
%
% 13
%
% 14
%
% 15
%
% 16
%
% Name Size Bytes Class Attributes
%
% CHx 1x16 1281792 cell
%
%
% ...Data Transfer Complete...
%%%
% * The data is saved to the workspace as a cell array named |CHx|.
% * A plot is produced of the captured data. An example is shown below.
%
% <<trans_cap_img.png>>
%
%% <trans_cap.html trans_cap.m>
%% <boot_complete.html boot_complete.m>
%% <set_sample_rate.html set_sample_rate.m>
%% <get_res.html get_res.m>
%% <calc_vsf.html calc_vsf.m>
%% <transient_commands.html transient_commands.m>
%% <monitor_log.html monitor_log.m>
%% <fetch_data.html fetch_data.m>
%% <plot_data.html plot_data.m>
%% <set_gains.html set_gains.m>
%% <get_gains.html get_gains.m>