@property |
|
def norders(self): |
|
""" |
|
Number of orders for this spectograph. |
|
""" |
|
self.check_disperser() |
|
if '10/mmLBSX' in self.dispname: |
|
return 4 |
|
elif '32/mm' in self.dispname: |
|
return 6 |
|
else: |
|
msgs.error('Unrecognized disperser') |
|
|
|
@property |
|
def order_spat_pos(self): |
|
""" |
|
Return the expected spatial position of each echelle order. |
|
""" |
|
self.check_disperser() |
|
if '10/mmLBSX' in self.dispname: |
|
return np.array([0.050, 0.215, 0.442, 0.759]) |
|
elif '32/mm' in self.dispname: |
|
#ToDo: create self.date similar to self.dispname and use that to decide which numbers to use |
|
## Old data, i.e. before 2011 |
|
#return np.array([0.241211 , 0.3173828, 0.387695, 0.456054, 0.530273, 0.640625]) |
|
##New data |
|
return np.array([0.2955097 , 0.37635756, 0.44952223, 0.51935601, 0.59489503, 0.70210309]) |
|
else: |
|
msgs.error('Unrecognized disperser') |
|
|
|
@property |
|
def orders(self): |
|
""" |
|
Return the order number for each echelle order. |
|
""" |
|
self.check_disperser() |
|
if '10/mmLBSX' in self.dispname: |
|
return np.arange(6,2,-1, dtype=int) |
|
elif '32/mm' in self.dispname: |
|
return np.arange(8,2,-1,dtype=int) |
|
else: |
|
msgs.error('Unrecognized disperser') |
|
|
|
@property |
|
def spec_min_max(self): |
|
""" |
|
Return the minimum and maximum spectral pixel expected for the |
|
spectral range of each order. |
|
""" |
|
# TODO: Why aren't these numbers in fraction of the detector |
|
# size instead of the pixel number? |
|
self.check_disperser() |
|
if '10/mmLBSX' in self.dispname: |
|
spec_max = np.asarray([1022, 1022, 1022, 1022]) |
|
spec_min = np.asarray([450, 0, 0, 0]) |
|
return np.vstack((spec_min, spec_max)) |
|
elif '32/mm' in self.dispname: |
|
spec_max = np.asarray([1022, 1022, 1022, 1022, 1022, 1022]) |
|
spec_min = np.asarray([512, 280, 0, 0, 0, 0]) |
|
return np.vstack((spec_min, spec_max)) |
|
else: |
|
msgs.error('Unrecognized disperser') |
The GNIRS spectrograph has multiple echelle gratings, and therefore the echelle-specific properties in the Class need to return different value based on which grating was used:
PypeIt/pypeit/spectrographs/gemini_gnirs.py
Lines 533 to 594 in 66b3791
The problem with the present implementation is the use of
self.dispname-- which is defined inconfig_specific_par()-- and how it gets propagated throughout the remainder of the PypeIt code base. For instance, the solution to #1977 (in PR #2013) involved additional gymnastics to satisfy Gemini/GNIRS that ends up callingconfig_specific_par().This is the only spectrograph to use
self.dispname, and it would be helpful to find another mechanism for specifying the echelle order information. In fact, there is a TODO in the GNIRS class about finding a way around this hack:PypeIt/pypeit/spectrographs/gemini_gnirs.py
Lines 470 to 472 in 66b3791