Notifications
You must be signed in to change notification settings - Fork 5
Expand file tree
/
Copy pathTemplate_LLwaveguide.py
More file actions
166 lines (124 loc) · 5.03 KB
/
Template_LLwaveguide.py
File metadata and controls
166 lines (124 loc) · 5.03 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
# -*- coding: utf-8 -*-
"""
Created on Mon Oct 19 12:12:06 2020
@author: Marc Bodem
Template for Calling CST from Python
- Lossy Load Waveguide (Microwave Studio)
- Parameter Sweep to load several sample points
- change 2 parameters
- Obtain S-Parameter values
"""
import sys
sys.path.append(r"C:\Program Files (x86)\CST Studio Suite 2020\AMD64\python_cst_libraries")
import cst
import cst.interface
import cst.results
import numpy as np
import scipy.stats
import time
import shutil
start = time.time()
# Local path to CST project file --> Please adapt
cst_path = r'D:\Documents\Vorlagen\CST_Python_Interface' # path
cst_project = '\Lossy Loaded Waveguide' # CST project
cst_project_path = cst_path + cst_project + '.cst'
cst_result_folder = cst_path + cst_project + '\Result'
# Delete all old results (if exist)
try:
shutil.rmtree(cst_result_folder)
except OSError as e:
print(e)
else:
print("The results directory is deleted successfully")
# Define random list of unifrom distributed sample points
Nmc = 3 # number of sample points
Nuq = 2 # number of parameters per sample point
means = [0.05,0.9] # mean values for parameters
sample_list = []
for nuq in range(Nuq):
mu = means[nuq]; uq = 0.2;
samples_k = scipy.stats.uniform.rvs(mu-uq*mu,2*uq*mu,Nmc)
sample_list.append(samples_k)
sample_list = np.array(sample_list).T
# Define list with frequency points of interest, here 0-7 GHz, Number of calculated points are set to 7001 in CST file, to get the desired frequencies.
freq_range = [80,90,100,110,120]
freq_range_pos_float = 0.1*(np.array(freq_range)-freq_range[0])*250
freq_range_pos= freq_range_pos_float.astype(int)
# Initialize lists with S-parameter results
S_all = []
S_real_all = []
S_imag_all = []
SdB_all = []
all_S_Para=[]
# Open CST as software
mycst=cst.interface.DesignEnvironment()
# Open CST Project
mycst1=cst.interface.DesignEnvironment.open_project(mycst,cst_project_path)
#Delete All Sequences before starting to get a fresh file
delete ='Sub Main() \n ParameterSweep.DeleteAllSequences() \nEnd Sub'
mycst1.schematic.execute_vba_code(delete, timeout=None)
for i in range(len(sample_list)):
#VBA Add Sequence
createSequence = 'Sub Main () \n ParameterSweep.AddSequence('+str(i)+') \n End Sub'
#VBA Add Parameters to Sequence. For each Parameter combination you want to test, create 1 sequence
add_Para_width = 'Sub Main () \n ParameterSweep.AddParameter('+str(i)+',"width",'+str(True)+','+str(sample_list[i][0])+','+str(sample_list[i][0])+','+str(1)+') \n End Sub'
add_Para_dist = 'Sub Main () \n ParameterSweep.AddParameter('+str(i)+',"dist",'+str(True)+','+str(sample_list[i][1])+','+str(sample_list[i][1])+','+str(1)+') \n End Sub'
#excute VBA Code above
mycst1.schematic.execute_vba_code(createSequence, timeout=None)
mycst1.schematic.execute_vba_code(add_Para_width, timeout=None)
mycst1.schematic.execute_vba_code(add_Para_dist, timeout=None)
#Start Solver
solve = 'Sub Main () \n ParameterSweep.Start \nEnd Sub'
mycst1.schematic.execute_vba_code(solve, timeout=None)
#Delete All Sequences
mycst1.schematic.execute_vba_code(delete, timeout=None)
#get project for results
project = cst.results.ProjectFile(cst_project_path, allow_interactive=True)
# Evaluate each sample point in CST
for i in range(len(sample_list)):
#k = i+1 because run Ids start at 1 and 0 is the current run
k=i+1
#get the actual results
results = project.get_3d().get_result_item(r"1D Results\S-Parameters\S1,1",k)
#get frequencies
freqs = results.get_xdata()
#get S-Parameter values
S_Para = results.get_ydata()
# Initialize value list for one MC sample point over all frequency points
freq_pos = []
freq = []
S = []
SdB = []
S_real = []
S_imag = []
# Get results for each freq. point of interest from CST
for j in range(len(freq_range)):
freq_pos_j = freq_range_pos[j]
freq_pos.append(freq_pos_j)
freq_value_j = freqs[freq_pos_j]
freq.append(freq_value_j)
S_real_j = S_Para[freq_pos_j].real
S_real.append(S_real_j)
S_imag_j = S_Para[freq_pos_j].imag
S_imag.append(S_imag_j)
S_j=np.sqrt(S_real_j**2+S_imag_j**2)
S.append(S_j)
S_dB_j = 20*np.log10(S_j)
SdB.append(S_dB_j)
# Add results to the lists for all sample points
S_all.append(S)
S_real_all.append(S_real)
S_imag_all.append(S_imag)
SdB_all.append(SdB)
#close CST
cst.interface.DesignEnvironment.close(mycst)
# Return results
print('\n frequency range in GHz:', freq_range)
print('frequency range as positions in CST:', freq_pos)
print('S-parameter:',S_all)
print('S-parameter (real part):',S_real_all)
print('S-parameter (imag part):',S_imag_all)
print('S-parameter (in dB):',SdB_all)
# Return runtime
end = time.time()
print('\n Runtime: {:5.3f}seconds'.format(end-start))