Notifications
You must be signed in to change notification settings - Fork 20
feat: add barseq instrument #1685
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from all commits
Commits
Show all changes
10 commits
Select commit
Hold shift + click to select a range
e29a652
feat: add barseq instrument
dbirman 6f193b8
refactor: SlapPlane -> Slap2Plane
dbirman 37e3230
Revert "refactor: SlapPlane -> Slap2Plane"
dbirman e26bf4d
chore: lint
dbirman 5377731
refactor: fix serialization code in example
dbirman 615dcb4
fix: fix issues blocking build
dbirman 6e032e7
Merge branch 'dev' into 1642-create-instrumentjson-generator-for-barseq
dbirman 4350803
Merge branch 'dev' into 1642-create-instrumentjson-generator-for-barseq
dbirman 81d3aa3
chore: fix write function for instrument example
dbirman 3b93a39
Merge branch '1642-create-instrumentjson-generator-for-barseq' of htt…
dbirman File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,250 @@ | ||
| """Example BarSEQ instrument schema""" | ||
|
|
||
| import argparse | ||
| from datetime import date | ||
|
|
||
| from aind_data_schema_models.modalities import Modality | ||
| from aind_data_schema_models.organizations import Organization | ||
| from aind_data_schema_models.units import SizeUnit | ||
|
|
||
| from aind_data_schema.components.coordinates import CoordinateSystemLibrary | ||
| from aind_data_schema.components.devices import ( | ||
| Camera, | ||
| DAQDevice, | ||
| Device, | ||
| Filter, | ||
| Laser, | ||
| Microscope, | ||
| Objective, | ||
| Cooling, | ||
| DataInterface, | ||
| CameraChroma, | ||
| BinMode | ||
| ) | ||
| from aind_data_schema.core.instrument import Instrument | ||
|
|
||
|
|
||
| objectives = [ | ||
| Objective( | ||
| name="20x Objective", | ||
| numerical_aperture=0.70, | ||
| magnification=20, | ||
| immersion="air", | ||
| manufacturer=Organization.NIKON, | ||
| model="CFI S Plan Fluor LWD 20XC", | ||
| ), | ||
| ] | ||
|
|
||
| dichroics = [ | ||
| Filter( | ||
| name="D1", | ||
| filter_type="Multiband", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF421/491/567/659/776-Di01", | ||
| notes="DAPI/GFP/RFP/Cy5/Cy7 dichroic", | ||
| center_wavelength=[421, 491, 567, 659, 776], | ||
| ), | ||
| Filter( | ||
| name="D2", | ||
| filter_type="Multiband", | ||
| manufacturer=Organization.CHROMA, | ||
| model="ZT405/514/635rpc", | ||
| notes="DAPI/YFP/Rs Cy5 dichroic", | ||
| center_wavelength=[405, 514, 635], | ||
| ), | ||
| Filter( | ||
| name="D3", | ||
| filter_type="Multiband", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF421/491/572-Di01-25x36", | ||
| notes="DAPI/GFP/TxRed dichroic", | ||
| center_wavelength=[421, 491, 572], | ||
| ), | ||
| ] | ||
|
|
||
| emission_filters = [ | ||
| Filter( | ||
| name="E1", | ||
| filter_type="Multiband", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF01-441/511/593/684/817", | ||
| notes="DAPI/GFP/Red/Cy5/Cy7 - used with D1 and 405nm laser", | ||
| center_wavelength=[441, 511, 593, 684, 817], | ||
| ), | ||
| Filter( | ||
| name="E2", | ||
| filter_type="Band pass", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF01-565/24", | ||
| notes="YFP - used with D2 and 520nm laser; bandwidth 24nm", | ||
| center_wavelength=565, | ||
| ), | ||
| Filter( | ||
| name="E3", | ||
| filter_type="Band pass", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF01-585/11", | ||
| notes="RFP - used with D1 and 546nm laser; bandwidth 11nm", | ||
| center_wavelength=585, | ||
| ), | ||
| Filter( | ||
| name="E4", | ||
| filter_type="Band pass", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF01-676/29", | ||
| notes="FarRed - used with D1 and 638nm laser; bandwidth 29nm", | ||
| center_wavelength=676, | ||
| ), | ||
| Filter( | ||
| name="E5", | ||
| filter_type="Band pass", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF01-775/140", | ||
| notes="RS Cy5 - used with D2 and 638nm laser; bandwidth 140nm", | ||
| center_wavelength=775, | ||
| ), | ||
| Filter( | ||
| name="E6", | ||
| filter_type="Multiband", | ||
| manufacturer=Organization.SEMROCK, | ||
| model="FF01-391/477/549/639/741-25", | ||
| notes="YFP/Rs Cy5", | ||
| center_wavelength=[391, 477, 549, 639, 741], | ||
| ), | ||
| Filter( | ||
| name="E7", | ||
| filter_type="Multiband", | ||
| manufacturer=Organization.CHROMA, | ||
| model="69401m", | ||
| notes="DAPI/GFP/TxRed", | ||
| center_wavelength=[440, 520, 600], | ||
| ), | ||
| Filter( | ||
| name="E8", | ||
| filter_type="Multiband", | ||
| manufacturer=Organization.CHROMA, | ||
| model="ZET532/640m", | ||
| notes="Alexa532/Cy5(wide)", | ||
| center_wavelength=[532, 640], | ||
| ), | ||
| ] | ||
|
|
||
| light_sources = [ | ||
| Laser( | ||
| name="Lumencor Celesta 365nm", | ||
| manufacturer=Organization.LUMENCOR, | ||
| model="Celesta", | ||
| wavelength=365, | ||
| ), | ||
| Laser( | ||
| name="Lumencor Celesta 440nm", | ||
| manufacturer=Organization.LUMENCOR, | ||
| model="Celesta", | ||
| wavelength=440, | ||
| ), | ||
| Laser( | ||
| name="Lumencor Celesta 488nm", | ||
| manufacturer=Organization.LUMENCOR, | ||
| model="Celesta", | ||
| wavelength=488, | ||
| ), | ||
| Laser( | ||
| name="Lumencor Celesta 514nm", | ||
| manufacturer=Organization.LUMENCOR, | ||
| model="Celesta", | ||
| wavelength=514, | ||
| ), | ||
| Laser( | ||
| name="Lumencor Celesta 561nm", | ||
| manufacturer=Organization.LUMENCOR, | ||
| model="Celesta", | ||
| wavelength=561, | ||
| ), | ||
| Laser( | ||
| name="Lumencor Celesta 640nm", | ||
| manufacturer=Organization.LUMENCOR, | ||
| model="Celesta", | ||
| wavelength=640, | ||
| ), | ||
| Laser( | ||
| name="Lumencor Celesta 730nm", | ||
| manufacturer=Organization.LUMENCOR, | ||
| model="Celesta", | ||
| wavelength=730, | ||
| ), | ||
| ] | ||
|
|
||
| camera = Camera( | ||
| name="Camera-1", | ||
| manufacturer=Organization.TELEDYNE_VISION_SOLUTIONS, | ||
| model="01-KINETIX-M-C", | ||
| data_interface=DataInterface.USB, | ||
| cooling=Cooling.AIR, | ||
| sensor_width=3200, | ||
| sensor_height=3200, | ||
| size_unit=SizeUnit.PX, | ||
| chroma=CameraChroma.BW, | ||
| immersion="air", | ||
| bin_mode=BinMode.NO_BINNING, | ||
| bit_depth=16, | ||
| sensor_format="20.8 x 20.8", | ||
| sensor_format_unit="mm", | ||
| frame_rate=500, | ||
| frame_rate_unit="hertz", | ||
| ) | ||
|
|
||
| microscope = Microscope( | ||
| name="Ti2-E__0", | ||
| manufacturer=Organization.NIKON, | ||
| model="Ti2-E", | ||
| ) | ||
|
|
||
| spinning_disk = Device( | ||
| name="XLIGHT Spinning Disk", | ||
| manufacturer=Organization.CRESTOPTICS, | ||
| model="X-Light V3", | ||
| notes="Nipkow spinning disk confocal module", | ||
| ) | ||
|
|
||
| daq = DAQDevice( | ||
| name="DigitalIO", | ||
| manufacturer=Organization.NATIONAL_INSTRUMENTS, | ||
| model="NI-DAQ Dev1", | ||
| data_interface="USB", | ||
| ) | ||
|
|
||
| instrument = Instrument( | ||
| location="243", | ||
| instrument_id="Dogwood", | ||
| modification_date=date(2024, 7, 9), | ||
| coordinate_system=CoordinateSystemLibrary.IMAGE_XYZ, | ||
| modalities=[Modality.BARSEQ], | ||
| notes=( | ||
| "BarSEQ imaging system with Nikon Ti2-E inverted microscope, X-Light V3 spinning disk confocal, " | ||
| "and Lumencor Celesta light engine. Used for multi-channel fluorescence imaging of genetically " | ||
| "modified tissue samples. Channel configurations: geneseq01/bcseq01 cycles use G/T/A/C/DAPI channels, " | ||
| "other geneseq/bcseq cycles use GTAC channels, hyb cycles use GFP/G/TxRed/Cy5/DAPI/DIC channels. " | ||
| "Camera pixel size: 0.33um. Stitch overlap: 23%. Hyb registration radius: 100um. " | ||
| "Configuration date corresponds to chprofile20x_dogwood_20240709.mat and chshift20x_dogwood_20240709.mat" | ||
| ), | ||
| temperature_control=False, | ||
| components=[ | ||
| microscope, | ||
| *objectives, | ||
| *dichroics, | ||
| *emission_filters, | ||
| *light_sources, | ||
| camera, | ||
| spinning_disk, | ||
| daq, | ||
| ], | ||
| ) | ||
|
|
||
| if __name__ == "__main__": | ||
| parser = argparse.ArgumentParser() | ||
| parser.add_argument("--output-dir", default=None, help="Output directory for generated JSON file") | ||
| args = parser.parse_args() | ||
|
|
||
| serialized = instrument.model_dump_json() | ||
| deserialized = Instrument.model_validate_json(serialized) | ||
| deserialized.write_standard_file(prefix="barseq", output_directory=args.output_dir) | ||
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!