# HX711S reliability design and implementation record

This document records the Centauri Carbon load-cell acquisition design, the
evidence used to choose it, and the exact remaining validation work. It is
intended to be sufficient for a future maintainer to reproduce the analysis
without rediscovering the electrical protocol or reverse engineering the
stock firmware again.

## Scope and evidence

The affected path is the four-channel `hx711s` sensor on the bed MCU:

```
HX711 DOUT/SCK pairs -> src/sensor_hx711s.c -> sensor_bulk records
-> klippy/extras/load_cell/hx711s.py -> load_cell.py / SOS filter
-> src/load_cell_probe.c -> trsync homing trigger
```

The reference material is deliberately preserved in
`/home/paul/carbon/cc-firmware/stock/strain-gauge-hx711/`:

* `HX711F_EN.pdf` — the HX711F data sheet used for the protocol limits;
* `firmware/upgrade_sg-1.6.9.bin` and `upgrade_sg-1.7.0.bin` — stock
Elegoo strain-gauge firmware;
* `r2/*.r2` — repeatable ARM Thumb r2ghidra scripts, with generated
pseudo-C beside them; and
* `COMPARISON.md` — version/hash and reverse-engineering notes.

Useful external references:

* [HX711F data sheet](https://cdn.sparkfun.com/assets/b/f/5/a/e/hx711F_EN.pdf)
* [Klipper HX711 discussion](https://klipper.discourse.group/t/hx711-support-load-cell-sensor/2057/8)
* [original upstream Klipper proposal](https://github.com/Klipper3d/klipper/pull/5492)
* [current upstream HX71x MCU code](https://github.com/Klipper3d/klipper/blob/7046bd00ef5c30dec6febc724f8d22967433c45c/src/sensor_hx71x.c)
* [Linux IIO HX711 driver](https://github.com/torvalds/linux/blob/248951ddc14de84de3910f9b13f51491a8cd91df/drivers/iio/adc/hx711.c)
* [Prusa HX717 implementation](https://github.com/prusa3d/Prusa-Firmware-Buddy/blob/e96ce2b92adcdafae19c132e76a81397b717e057/src/common/hx717.cpp)

## What the hardware requires

The data sheet makes the MCU, not Python, the only place that can decide if a
serial frame was acquired correctly:

| Requirement | Consequence in this driver |
| --- | --- |
| DOUT low means a conversion is ready; SCK must remain low while waiting. | A pre-read high DOUT makes the whole lock-step frame invalid. |
| Read 24 data bits, then 1/2/3 gain-selection pulses. | Check every extra bit and record its failure. |
| SCK high/low is 0.2–50 us; high for more than 60 us powers down the chip. | Clock transitions are explicit; IRQs are masked only for the 1-us high phase. |
| Results are signed 24-bit two's complement. | Sign extension remains in MCU code and rail values are flagged. |
| After reset or a gain change, four conversions must settle (50 ms at 80 SPS, 400 ms at 10 SPS). | Reset is followed by five discarded frames (gain-select plus four settling conversions), then two clean qualification frames. |

## Comparative audit

| Area | Previous Cosmos behavior | Elegoo / upstream / Prusa lesson | Selected behavior |
| --- | --- | --- | --- |
| Frame error handling | MCU and host each used different error heuristics; Python could replace an invalid value with a prior one. | Linux and Prusa treat the serial transaction as one acquisition operation; Elegoo keeps this low-level logic inside its MCU blob. | **MCU owns validity** and emits a quality word with every raw record. Invalid values are diagnostic-only. |
| Startup | Data was accepted immediately after command/restart. | The data sheet requires four settling conversions; upstream also has reset/start sequencing. | Explicit power-down/reset, 50-ms start delay, five discarded and two qualified frames. |
| DOUT protocol | A missed/late line could become a normal sample or a host-side `100000`-count error. | Stock firmware waits for ready, shifts 24 + gain bits under a protected timing window; no source supports fabricating data. | Pre-ready, gain-bit, post-read-low, overrun, and rail checks become quality flags; protocol faults reset the acquisition state. |
| Triggering | One filtered sample could trigger; `abs(INT32_MIN)` was unsafe. | Noise must be rejected before a physical endstop decision. | Invalid acquisition immediately reports a homing fault; two consecutive qualified filtered samples are required to trigger. |
| Tare | Arithmetic mean over a short time window. | Elegoo calibrates over 30 samples; median resists a remaining impulsive sample. | Per-channel 30-sample median baseline. |
| Filter updates | The command-time override could update the wrong design state. | Filter state and coefficients must change atomically at the defined boundary. | Correct command object/state update and signed fixed-point bounds. |

The decompiled Elegoo 1.6.9 and 1.7.0 images show the same essential
low-level pattern: bounded ready polling, 24-bit shift plus gain clocks,
sign extension, and protection around the transfer. They do **not** expose
the higher-level policy, so they support the protocol decisions but not a
claim that their opaque filtering/threshold policy is superior.

## Chosen implementation

Kalico commit `8433f46d569694ab136fc90696031ec68ef4270d` implements the
following contract.

1. `sensor_hx711s.c` appends `sensor_count` signed raw counts followed by one
unsigned 32-bit quality word. Bits 8–11 identify affected channels;
low bits identify settling, not-ready, bad gain clocks, post-read-low,
capture overrun, and exact ADC rails.
2. `hx711s.py` drops any nonzero-quality frame before it reaches a client. It
retains `{time, counts, quality}` in the batch's `faults` field for logs
and diagnostics. There is no held-value synthesis, fixed count threshold,
or Python-side acquisition restart.
3. The MCU performs recovery. A protocol fault starts a deterministic reset;
settling and qualifying records remain visible but are never control data.
4. If a probe is active, an invalid frame ends the move with the dedicated
`invalid HX711 sample` trsync reason. This is deliberately fail-safe:
continuing Z motion after a broken acquisition is worse than a retry.
5. Valid filtered force must cross the configured threshold twice in a row.
At the normal 80 SPS this costs at most 12.5 ms and removes the last
plausible single-frame trigger path.
6. All other bulk ADC implementations explicitly emit an empty `faults` list
so the common `BulkAdcData` interface stays uniform.

### Rejected alternatives

* **Keep a last known-good value.** It makes graphs look continuous, but it
falsely asserts a force that was never measured and can contaminate tare,
filtering, and a probe decision. Rejected.
* **Retry only in Python.** It cannot establish whether SCK timing or the
gain-selection pulses were valid. It also races MCU-triggered homing.
Rejected.
* **Ignore a single bad channel in a four-cell sum.** This turns a hardware
disagreement into a plausible but wrong force and hides a wiring/thermal
fault. Rejected for probing; a future diagnostic-only degraded mode may be
useful, but must never drive Z motion.
* **Longer digital filtering instead of frame validity.** It may hide bad
data but cannot distinguish a real load from a malformed serial transfer.
Rejected as the primary defense.
* **One very long startup discard.** Simple but needlessly delays a probe.
The selected 5+2 sequence honors the data-sheet four-conversion rule and
separately proves two usable frames.

## Incident interpretation

The current issue evidence includes repeated `192`-count glitches, commonly
on channels 1/2, and occasional `-1` values during hot-chamber probing
(>50 C chamber, 105 C bed). Those are acquisition faults this design makes
visible and fail-safe rather than silently substituting.

One later `sensor_bulk_status` error in the same log must **not** be counted
as an independent HX711 fault: it followed `Heater heater_bed not heating at
expected rate` and the resulting global emergency shutdown. The probe
failures and 192/-1 glitches remain the relevant HX711 evidence.

## Validation and rollout checklist

The code has passed Python byte-compilation and an STM32F401 bed-MCU build
using the CC1 configuration. It has not yet earned a reliability claim on a
printer. Before enabling it for normal operation:

1. Build the Cosmos image with the recipe revision below; confirm its Kalico
host package and bed-MCU firmware both derive from `8433f46d`.
2. Flash an idle CC1, restart Klipper, and confirm four clean channels in the
load-cell status stream after the startup discard period.
3. Run at least 30 unloaded tare samples; record per-channel medians and
spread. A large channel spread is a hardware diagnostic, not a reason to
relax validity checks.
4. Run repeated cold bed probes, then controlled hot tests at 105 C bed and
>50 C chamber. Record every quality word, trsync error, false trigger,
timeout, and successful probe position.
5. Inject/observe a disconnected DOUT or forced not-ready condition only
while the machine is safe. Verify that active homing aborts without Z
overtravel and that normal sampling recovers after reset.
6. Compare repeated-probe repeatability and failure rate against the current
firmware. Do not tune the trigger threshold merely to mask a channel
quality fault.
7. If a valid, stable sample stream still exhibits false triggers, add a
configurable per-channel disagreement limit and report it separately from
protocol quality. Keep that policy outside the serial framing code.

## Cosmos integration

`meta-opencentauri/recipes-apps/klipper/kalico_2026.02.00.inc` should point
at branch `paul/hx711-reliability`, revision
`8433f46d569694ab136fc90696031ec68ef4270d`, remove the obsolete
`0003-fix-hx711s-mcu-glitch-filter.patch`, and increment `PR` to `r9`.
That patch was a narrow stopgap for duplicate callbacks; the new revision
removes the divergence instead of layering another conflicting fix on top.
2 changes: 1 addition & 1 deletion meta-opencentauri/recipes-apps/klipper/files/macros.cfg
Original file line number Diff line number Diff line change
Expand Up @@ -524,7 +524,7 @@ gcode:
{% for _ in range(2) %}
G90
G1 X120 Y-1 F9000
PROBE HOME=Z SAMPLES=3 SAMPLES_TOLERANCE=0.05 BAD_PROBE_RETRIES=3 BAD_PROBE_STRATEGY=RETRY ; Cleaning passes
PROBE HOME=Z SAMPLES=3 SAMPLES_TOLERANCE=0.1 BAD_PROBE_RETRIES=3 BAD_PROBE_STRATEGY=RETRY ; Cleaning passes
G91
G0 X4 F600
G0 Z0.8 F300 ; Using pressure of bending the build plate to squish filament
Expand Down
6 changes: 3 additions & 3 deletions meta-opencentauri/recipes-apps/klipper/kalico_2026.02.00.inc
Original file line number Diff line number Diff line change
Expand Up @@ -4,7 +4,7 @@ LIC_FILES_CHKSUM = "file://COPYING;md5=1ebbd3e34237af26da5dc08a4e440464"

FILESEXTRAPATHS:prepend := "${THISDIR}/files:"

SRC_URI = "git://github.com/OpenCentauri/kalico.git;protocol=https;branch=hx711s-new \
SRC_URI = "git://github.com/OpenCentauri/kalico.git;protocol=https;branch=paul/hx711-reliability \
file://0001-remove-save-config-subfile-check.patch \
file://0002-reduce-calibration-difference-tolerance.patch \
file://0001-Reduce-log-rotate-threshold.patch \
Expand All @@ -13,9 +13,9 @@ SRC_URI = "git://github.com/OpenCentauri/kalico.git;protocol=https;branch=hx711s
file://0001-probe-home-z-includes-z-offset.patch \
file://0001-force-specific-input-shaper.patch \
"
SRCREV = "413e9e3886463d42b5c3fad678969962dac1ab0f"
SRCREV = "c368f84ec516f5d639aeddcb99d2c967957ab8e7"

PR = "r8"
PR = "r10"

S = "${WORKDIR}/git"

Expand Down
Loading