96 changes: 48 additions & 48 deletions docs/DEVICE_STATUS_FIELDS.rst
Original file line number Diff line number Diff line change
Expand Up @@ -29,10 +29,10 @@ This document lists the fields found in the ``status`` object of device status m
- Status of special functions (e.g., freeze protection, anti-seize operations).
- None
* - ``didReload``
- integer
- bool
- None
- Indicates if the device has recently reloaded or restarted.
- None
- Converted from integer (0 or 1) to bool
* - ``errorCode``
- integer
- None
Expand All @@ -49,25 +49,25 @@ This document lists the fields found in the ``status`` object of device status m
- The current **actual operational state** of the device (what it's doing RIGHT NOW). Reports status values: 0=Standby, 32=Heat Pump active, 64=Energy Saver active, 96=High Demand active. See Operation Modes section below for the critical distinction between this and ``dhwOperationSetting``.
- None
* - ``operationBusy``
- integer
- None
- Indicates if the device is currently performing heating operations (1=busy, 0=idle).
- bool
- None
- Indicates if the device is currently performing heating operations (True=busy, False=idle).
- Converted from integer (0 or 1) to bool
* - ``freezeProtectionUse``
- integer
- bool
- None
- Whether freeze protection is active. When tank water temperature falls below 43°F (6°C), the electric heater activates to prevent freezing.
- None
- Converted from integer (0 or 1) to bool
* - ``dhwUse``
- integer
- bool
- None
- Domestic Hot Water (DHW) usage status - indicates if hot water is currently being drawn from the tank.
- None
- Converted from integer (0 or 1) to bool
* - ``dhwUseSustained``
- integer
- bool
- None
- Sustained DHW usage status - indicates prolonged hot water usage.
- None
- Converted from integer (0 or 1) to bool
* - ``dhwTemperature``
- integer
- °F
Expand All @@ -79,10 +79,10 @@ This document lists the fields found in the ``status`` object of device status m
- Target DHW temperature setting. Range: 95°F (35°C) to 150°F (65.5°C). Default: 120°F (49°C).
- ``raw + 20``
* - ``programReservationUse``
- integer
- bool
- None
- Whether a program reservation (scheduled operation) is in use.
- None
- Converted from integer (0 or 1) to bool
* - ``smartDiagnostic``
- integer
- None
Expand All @@ -104,10 +104,10 @@ This document lists the fields found in the ``status`` object of device status m
- WiFi signal strength in dBm (decibel-milliwatts). Typical values: -30 (excellent) to -90 (poor).
- None
* - ``ecoUse``
- integer
- bool
- None
- Whether ECO (Energy Cut Off) safety feature has been triggered. The ECO switch is a high-temperature safety limit.
- None
- Converted from integer (0 or 1) to bool
* - ``dhwTargetTemperatureSetting``
- integer
- °F
Expand Down Expand Up @@ -149,40 +149,40 @@ This document lists the fields found in the ``status`` object of device status m
- Target superheat value - the desired temperature difference ensuring complete refrigerant vaporization.
- ``raw / 10.0``
* - ``compUse``
- integer
- None
- Compressor usage status (1=On, 0=Off). The compressor is the main component of the heat pump.
- bool
- None
- Compressor usage status (True=On, False=Off). The compressor is the main component of the heat pump.
- Converted from integer (0 or 1) to bool
* - ``eevUse``
- integer
- None
- Electronic Expansion Valve (EEV) usage status (1=active, 0=inactive). The EEV controls refrigerant flow.
- bool
- None
- Electronic Expansion Valve (EEV) usage status (True=active, False=inactive). The EEV controls refrigerant flow.
- Converted from integer (0 or 1) to bool
* - ``evaFanUse``
- integer
- None
- Evaporator fan usage status (1=On, 0=Off). The fan pulls ambient air through the evaporator coil.
- bool
- None
- Evaporator fan usage status (True=On, False=Off). The fan pulls ambient air through the evaporator coil.
- Converted from integer (0 or 1) to bool
* - ``currentInstPower``
- integer
- W
- Current instantaneous power consumption in Watts. Does not include heating element power when active.
- None
* - ``shutOffValveUse``
- integer
- bool
- None
- Shut-off valve usage status. The valve controls refrigerant flow in the system.
- None
- Converted from integer (0 or 1) to bool
* - ``conOvrSensorUse``
- integer
- bool
- None
- Condensate overflow sensor usage status.
- None
- Converted from integer (0 or 1) to bool
* - ``wtrOvrSensorUse``
- integer
- bool
- None
- Water overflow/leak sensor usage status. Triggers error E799 if leak detected.
- None
- Converted from integer (0 or 1) to bool
* - ``dhwChargePer``
- integer
- %
Expand All @@ -209,20 +209,20 @@ This document lists the fields found in the ``status`` object of device status m
- Freeze protection temperature setting.
- ``raw + 20``
* - ``antiLegionellaUse``
- integer
- bool
- None
- Whether anti-legionella function is enabled.
- None
- Converted from integer (0 or 1) to bool
* - ``antiLegionellaPeriod``
- integer
- days
- Anti-legionella function period.
- None
* - ``antiLegionellaOperationBusy``
- integer
- bool
- None
- Whether the anti-legionella function is busy.
- None
- Converted from integer (0 or 1) to bool
* - ``programReservationType``
- integer
- None
Expand All @@ -244,15 +244,15 @@ This document lists the fields found in the ``status`` object of device status m
- Temperature formula type.
- None
* - ``errorBuzzerUse``
- integer
- bool
- None
- Whether the error buzzer is enabled.
- None
- Converted from integer (0 or 1) to bool
* - ``currentHeatUse``
- integer
- bool
- None
- Current heat usage.
- None
- Converted from integer (0 or 1) to bool
* - ``currentInletTemperature``
- float
- °F
Expand Down Expand Up @@ -304,25 +304,25 @@ This document lists the fields found in the ``status`` object of device status m
- Current superheat value - actual temperature difference between suction and evaporator temperatures.
- ``raw / 10.0``
* - ``heatUpperUse``
- integer
- None
- Upper electric heating element usage status (1=On, 0=Off). Power: 3,755W @ 208V or 5,000W @ 240V.
- bool
- None
- Upper electric heating element usage status (True=On, False=Off). Power: 3,755W @ 208V or 5,000W @ 240V.
- Converted from integer (0 or 1) to bool
* - ``heatLowerUse``
- integer
- None
- Lower electric heating element usage status (1=On, 0=Off). Power: 3,755W @ 208V or 5,000W @ 240V.
- bool
- None
- Lower electric heating element usage status (True=On, False=Off). Power: 3,755W @ 208V or 5,000W @ 240V.
- Converted from integer (0 or 1) to bool
* - ``scaldUse``
- integer
- bool
- None
- Scald protection active status. Displays warning when water temperature reaches levels that could cause scalding.
- None
- Converted from integer (0 or 1) to bool
* - ``airFilterAlarmUse``
- integer
- bool
- None
- Air filter alarm usage - indicates if air filter maintenance reminder is enabled.
- None
- Converted from integer (0 or 1) to bool
* - ``airFilterAlarmPeriod``
- integer
- hours
Expand Down