86 changes: 43 additions & 43 deletions docs/protocol/data_conversions.rst
Original file line number Diff line number Diff line change
Expand Up @@ -18,26 +18,25 @@ Raw Encoding Strategies

The device uses several encoding schemes to minimize transmission overhead:

1. **Offset Encoding** (add_20)
- Applied to most temperature fields
- Formula: ``displayed_value = raw_value + 20``
- Purpose: Negative temperatures stored as positive integers
- Range: Typically -4°F (-20°C) to 149°F (65°C)
- Example: Raw 100 → 120°F display value

2. **Tenths Encoding** (div_10)
1. **Half-degree Celsius to Fahrenheit** (HalfCelsiusToF)
- Applied to most temperature fields that are not scaled by other factors.
- Formula: ``displayed_value = (raw_value / 2.0) * 9/5 + 32``
- Purpose: Converts raw values, which are in half-degrees Celsius, to Fahrenheit.
- Example: Raw 122 -> (122 / 2) * 9/5 + 32 = 141.8°F

2. **Scaled Celsius to Fahrenheit** (PentaCelsiusToF)
- Applied to refrigerant and evaporator temperatures.
- Formula: ``displayed_value = (raw_value / 5.0) * 9/5 + 32``
- Purpose: Converts raw values, which are scaled by a factor of 5, to Fahrenheit.
- Example: Raw 250 -> (250 / 5) * 9/5 + 32 = 122°F

3. **Tenths Encoding** (div_10)
- Applied to decimal precision values
- Formula: ``displayed_value = raw_value / 10.0``
- Purpose: Preserve decimal precision in integer storage
- Common for flow rates and differential temperatures
- Example: Raw 125 → 12.5 GPM

3. **Decicelsius to Fahrenheit** (decicelsius_to_f)
- Applied to refrigerant and evaporator temperatures
- Formula: ``displayed_value = (raw_value / 10) * 9/5 + 32``
- Purpose: Convert Celsius tenths to Fahrenheit
- Example: Raw 250 (25°C) → 77°F

4. **Boolean Encoding** (device_bool)
- Applied to all status flags
- Formula: ``displayed_value = (raw_value == 2)``
Expand Down Expand Up @@ -66,23 +65,23 @@ DHW (Domestic Hot Water) Temperatures
- Display Unit
- Description
* - ``dhwTemperature``
- add_20
- HalfCelsiusToF
- °F
- **Current outlet temperature** of hot water being delivered to fixtures. Real-time measurement. Typically 90-150°F.
* - ``dhwTemperature2``
- add_20
- HalfCelsiusToF
- °F
- **Secondary DHW temperature sensor** reading (redundancy/averaging). May differ slightly from primary sensor during temperature transitions.
* - ``dhwTemperatureSetting``
- add_20
- HalfCelsiusToF
- °F
- **User-configured target temperature** for DHW delivery. Adjustable range: 95-150°F. Default: 120°F. This is the setpoint users configure in the app.
* - ``currentInletTemperature``
- div_10
- °F
- **Cold water inlet temperature** to the water heater. Affects heating performance and recovery time. Typically 40-80°F depending on season and location.
* - ``dhwTargetTemperatureSetting``
- add_20
- HalfCelsiusToF
- °F
- **Duplicate of dhwTemperatureSetting** for legacy API compatibility.

Expand All @@ -98,11 +97,11 @@ Tank Temperature Sensors
- Display Unit
- Description
* - ``tankUpperTemperature``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Upper tank sensor temperature**. Indicates stratification - hot water at top for quick delivery. Typically hottest point in tank.
* - ``tankLowerTemperature``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Lower tank sensor temperature**. Indicates bulk tank temperature and heating progress. Typically cooler than upper sensor.

Expand All @@ -122,27 +121,27 @@ These temperatures monitor the heat pump refrigerant circuit health and performa
- Display Unit
- Description
* - ``dischargeTemperature``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Compressor discharge temperature**. Temperature of refrigerant exiting the compressor. Typically 120-180°F. High values indicate high system pressure; low values indicate efficiency issues.
* - ``suctionTemperature``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Compressor suction temperature**. Temperature of refrigerant entering the compressor. Typically 40-60°F. Affects superheat calculation.
* - ``evaporatorTemperature``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Evaporator coil temperature**. Where heat is extracted from ambient air. Typically 20-50°F. Lower outdoor air temperature reduces evaporator efficiency.
* - ``ambientTemperature``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Ambient air temperature** measured at heat pump inlet. Directly affects system performance. At freezing (32°F), heat pump efficiency drops significantly.
* - ``targetSuperHeat``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Target superheat setpoint**. Desired temperature difference between suction and evaporator ensuring complete refrigerant vaporization. Typically 10-20°F.
* - ``currentSuperHeat``
- decicelsius_to_f
- PentaCelsiusToF
- °F
- **Measured superheat value**. Actual temperature difference. Deviation from target indicates EEV (Electronic Expansion Valve) control issues.

Expand All @@ -166,19 +165,19 @@ Electric heating elements are controlled via thermostat ranges. Two sensors (upp
- Display Unit
- Description
* - ``heUpperOnTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Upper element ON threshold**. Upper tank temp must fall below this to activate upper heating element.
* - ``heUpperOffTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Upper element OFF threshold**. Upper tank temp rises above this to deactivate upper element (hysteresis).
* - ``heLowerOnTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Lower element ON threshold**. Lower tank temp must fall below this to activate lower element.
* - ``heLowerOffTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Lower element OFF threshold**. Lower tank temp rises above this to deactivate lower element.
* - ``heUpperOnDiffTempSetting``
Expand All @@ -198,7 +197,7 @@ Electric heating elements are controlled via thermostat ranges. Two sensors (upp
- °F
- **Lower element differential** variation.
* - ``heatMinOpTemperature``
- add_20
- HalfCelsiusToF
- °F
- **Minimum heat pump operation temperature**. Lowest tank temperature setpoint allowed in the current operating mode. Range: 95-113°F. Default: 95°F. When set, the user can only set the target tank temperature at or above this threshold, ensuring minimum system operating conditions.

Expand All @@ -216,19 +215,19 @@ Heat pump stages are similarly controlled via thermostat ranges:
- Display Unit
- Description
* - ``hpUpperOnTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Upper heat pump ON**. Upper tank falls below this to activate heat pump for upper tank heating.
* - ``hpUpperOffTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Upper heat pump OFF**. Upper tank rises above this to stop upper tank heat pump operation.
* - ``hpLowerOnTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Lower heat pump ON**. Lower tank falls below this to activate heat pump for lower tank heating.
* - ``hpLowerOffTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Lower heat pump OFF**. Lower tank rises above this to stop lower tank heat pump operation.
* - ``hpUpperOnDiffTempSetting``
Expand Down Expand Up @@ -264,15 +263,15 @@ Freeze Protection Temperatures
- Boolean
- **Freeze protection enabled flag**. When True, triggers anti-freeze operation below threshold.
* - ``freezeProtectionTemperature``
- add_20
- HalfCelsiusToF
- °F
- **Freeze protection temperature setpoint**. Range: 43-50°F (6-10°C). Default: 43°F (6°C). When tank temperature drops below this, electric heating activates automatically to prevent freezing.
* - ``freezeProtectionTempMin``
- add_20
- HalfCelsiusToF
- °F
- **Minimum freeze protection temperature limit** (lower boundary). Fixed at 43°F (6°C).
* - ``freezeProtectionTempMax``
- add_20
- HalfCelsiusToF
- °F
- **Maximum freeze protection temperature limit** (upper boundary). Fixed at 50°F (10°C).

Expand All @@ -290,18 +289,19 @@ For systems with recirculation pumps (optional feature):
- Display Unit
- Description
* - ``recircTemperature``
- add_20
- HalfCelsiusToF
- °F
- **Recirculation loop current temperature**. Temperature of water being circulated back to tank.
* - ``recircFaucetTemperature``
- add_20
- HalfCelsiusToF
- °F
- **Recirculation faucet outlet temperature**. How hot water is at the furthest fixture during recirculation.
* - ``recircTempSetting``
- add_20
- HalfCelsiusToF
- °F
- **Recirculation target temperature**. What temperature to maintain in the recirculation line.


Flow Rate Fields
----------------

Expand Down Expand Up @@ -613,8 +613,8 @@ Temperature Unit Notes
* **Fahrenheit** conversions assume target display is °F as configured in the device
* **Celsius calculations** can be derived by reversing the conversions:

- From ``add_20`` fields: ``celsius = (fahrenheit - 20) * 5/9``
- From ``decicelsius_to_f`` fields: ``celsius = (fahrenheit - 32) * 5/9``
- From ``HalfCelsiusToF`` fields: ``celsius = (fahrenheit - 32) * 5/9 * 2``
- From ``PentaCelsiusToF`` fields: ``celsius = (fahrenheit - 32) * 5/9 * 5``
- From ``div_10`` fields: ``celsius = value_celsius / 10.0``

* **Sensor Accuracy**: Typically ±2°F for tank sensors, ±3°F for refrigerant sensors
Expand Down
46 changes: 23 additions & 23 deletions docs/protocol/device_status.rst
Original file line number Diff line number Diff line change
Expand Up @@ -77,12 +77,12 @@ This document lists the fields found in the ``status`` object of device status m
- integer
- °F
- Current Domestic Hot Water (DHW) outlet temperature.
- ``raw + 20``
- HalfCelsiusToF
* - ``dhwTemperatureSetting``
- integer
- °F
- Target DHW temperature setting. Range: 95°F (35°C) to 150°F (65.5°C). Default: 120°F (49°C).
- ``raw + 20``
- HalfCelsiusToF
* - ``programReservationUse``
- bool
- None
Expand Down Expand Up @@ -117,42 +117,42 @@ This document lists the fields found in the ``status`` object of device status m
- integer
- °F
- The target DHW temperature setting (same as dhwTemperatureSetting).
- ``raw + 20``
- HalfCelsiusToF
* - ``tankUpperTemperature``
- integer
- °F
- Temperature of the upper part of the tank.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``tankLowerTemperature``
- integer
- °F
- Temperature of the lower part of the tank.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``dischargeTemperature``
- integer
- °F
- Compressor discharge temperature - temperature of refrigerant leaving the compressor.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``suctionTemperature``
- integer
- °F
- Compressor suction temperature - temperature of refrigerant entering the compressor.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``evaporatorTemperature``
- integer
- °F
- Evaporator temperature - temperature where heat is absorbed from ambient air.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``ambientTemperature``
- integer
- °F
- Ambient air temperature measured at the heat pump air intake.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``targetSuperHeat``
- integer
- °F
- Target superheat value - the desired temperature difference ensuring complete refrigerant vaporization.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``compUse``
- bool
- None
Expand Down Expand Up @@ -212,7 +212,7 @@ This document lists the fields found in the ``status`` object of device status m
- integer
- °F
- Freeze protection temperature setpoint. Range: 43-50°F (6-10°C), Default: 43°F. When tank temperature drops below this, electric heating activates automatically to prevent freezing.
- ``raw + 20``
- HalfCelsiusToF
* - ``antiLegionellaUse``
- bool
- None
Expand Down Expand Up @@ -287,7 +287,7 @@ This document lists the fields found in the ``status`` object of device status m
- integer
- °F
- Second DHW temperature reading.
- ``raw + 20``
- HalfCelsiusToF
* - ``currentDhwFlowRate``
- float
- GPM
Expand All @@ -307,7 +307,7 @@ This document lists the fields found in the ``status`` object of device status m
- integer
- °F
- Current superheat value - actual temperature difference between suction and evaporator temperatures.
- ``(raw / 10) * 9/5 + 32`` (decicelsius to Fahrenheit)
- PentaCelsiusToF
* - ``heatUpperUse``
- bool
- None
Expand Down Expand Up @@ -357,42 +357,42 @@ This document lists the fields found in the ``status`` object of device status m
- integer
- °F
- Heat pump upper on temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``hpUpperOffTempSetting``
- integer
- °F
- Heat pump upper off temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``hpLowerOnTempSetting``
- integer
- °F
- Heat pump lower on temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``hpLowerOffTempSetting``
- integer
- °F
- Heat pump lower off temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``heUpperOnTempSetting``
- integer
- °F
- Heater element upper on temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``heUpperOffTempSetting``
- integer
- °F
- Heater element upper off temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``heLowerOnTempSetting``
- integer
- °F
- Heater element lower on temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``heLowerOffTempSetting``
- integer
- °F
- Heater element lower off temperature setting.
- ``raw + 20``
- HalfCelsiusToF
* - ``hpUpperOnDiffTempSetting``
- float
- °F
Expand Down Expand Up @@ -437,7 +437,7 @@ This document lists the fields found in the ``status`` object of device status m
- float
- °F
- Minimum heat pump operation temperature. Lowest tank temperature setpoint allowed in the current operating mode (95-113°F, default 95°F). When set, users can only set the target tank temperature at or above this threshold.
- ``raw + 20``
- HalfCelsiusToF
* - ``drOverrideStatus``
- integer
- None
Expand Down Expand Up @@ -730,7 +730,7 @@ Technical Notes

* Tank temperature sensors operate within -4°F to 149°F (-20°C to 65°C)
* Outside normal range, system may operate with reduced capacity using opposite heating element
* All tank temperature readings use conversion formula: ``display_temp = raw + 20``