International Space Station Data Stream

Screenshot of Node-RED with the ISS Data Stream node in use

This is a Node-RED node that wraps the I.S.S. Lightstreamer feed, emitting real-time telemetry from the International Space Station.

It was heavily inspired by the ISS Mimic Project, and this node can be used in Node-RED to create your own ISS Mimic and Dashboard.

How to use

  1. Install Node-RED
  2. Add this node via the Node-RED Palette Manager
  3. Drag the ISS Data node onto your flow
  4. Wire it to a "debug" node, and you can then see the output in the Node-RED debug panel

Node Output

The node can output three different types of data:

  • Raw: The raw data from the Lightstreamer feed, with no modifications
  • Formatted: Each feed has a designated type, this output type will format the data into a more human-readable format, so numbers will display as numbers, or any feed with a key map (e.g. 0=OFF, 1=ON) will output the human-readable format
  • Both: This outputs a JSON structure with the keys raw and formatted, so you can access both data types

Examples

You can find example flows inside the /examples folder. One for a basic debug output, and another for a more advanced dashboard that uses FlowFuse Dashboard:

With the following flow (included in /examples)

Example FlowFuse Dashboard showing some data feeds from the International Space Station

You will build the following Dashboard:

Example FlowFuse Dashboard showing some data feeds from the International Space Station

Data Feeds

The data included with the stream is extensive, you can toggle on/off different feeds within the node's configuration options.

ADCO

Key Description Property Type
USLAB000001 Control Moment Gyroscope (CMG)-1 On-Line 0=NOT IN USE | 1=IN USE
USLAB000002 Control Moment Gyroscope (CMG)-2 On-Line 0=NOT IN USE | 1=IN USE
USLAB000003 Control Moment Gyroscope (CMG)-3 On-Line 0=NOT IN USE | 1=IN USE
USLAB000004 Control Moment Gyroscope (CMG)-4 On-Line 0=NOT IN USE | 1=IN USE
USLAB000005 Number of Control Moment Gyroscope (CMG)s Online {0:d0}
USLAB000006 Control Moment Gyroscope (CMG) Control Torque - Roll (N-m) {0:f4}
USLAB000007 Control Moment Gyroscope (CMG) Control Torque - Pitch (N-m) {0:f4}
USLAB000008 Control Moment Gyroscope (CMG) Control Torque - Yaw (N-m) {0:f4}
USLAB000009 Active Control Moment Gyroscope (CMG) Momentum (Nms) {0:d0}
USLAB000011 Desaturation Request (Enabled/Inhibited) 0=ENABLED | 1=INHIBITED
USLAB000013 US Attitude Source 0=NONE\
USLAB000014 US Rate Source 0=NONE | 1=RGA1 | 2=RGA2 | 3=RUSSIAN
USLAB000015 US State Vector Source 0=NO_SOURCE | 1=Unused | 2=Unused | 3=RUSSIAN | 4=GPS1_DETERMINISTIC | 5=GPS2_DETERMINISTIC | 6=GROUND
USLAB000016 Attitude Controller Type 0=ATTITUDE HOLD | 1=TEA
USLAB000017 Attitude Control Reference Frame 0=LVLH | 1=Inertial | 2=XPOP
USLAB000018 US Current Local Vertical Local Horizontal (LVLH) Attitude Quaternion Component 0 {0:f2}
USLAB000019 US Current Local Vertical Local Horizontal (LVLH) Attitude Quaternion Component 1 {0:f2}
USLAB000020 US Current Local Vertical Local Horizontal (LVLH) Attitude Quaternion Component 2 {0:f2}
USLAB000021 US Current Local Vertical Local Horizontal (LVLH) Attitude Quaternion Component 3 {0:f2}
USLAB000022 US Attitude Roll Error (deg) {0:f2}
USLAB000023 US Attitude Pitch Error (deg) {0:f2}
USLAB000024 US Attitude Yaw Error (deg) {0:f2}
USLAB000025 US Commanded Attitude Quaternion Component 0 {0:f2}
USLAB000026 US Commanded Attitude Quaternion Component 1 {0:f2}
USLAB000027 US Commanded Attitude Quaternion Component 2 {0:f2}
USLAB000028 US Commanded Attitude Quaternion Component 3 {0:f2}
USLAB000038 Active Control Moment Gyroscope (CMG) Momentum Capacity (Nms) {0:d0}
USLAB000039 ISS Total Mass (kg) {0:d0}
USLAB000040 Solar Beta Angle (degrees) {0:f2}
USLAB000041 Loss of CMG Attitude Control (LOAC) Caution Message In Alarm 0=FALSE | 1=TRUE
USLAB000042 Loss of ISS Attitude Control (LOAC) Caution Message In Alarm 0=FALSE | 1=TRUE
USLAB000043 Global Positioning System (GPS-1) Ops Status 0=DOING POSITION FIXES | 1=SV TIMING | 2=APPROXIMATE TIMING | 3=GPS TIME | 4=NEED INITIALIZATION | 5=GDOP NEEDED | 6=BAD TIMING | 7=NO USABLE SV | 8=ONLY 1 USABLE SVs | 9=ONLY 2 USABLE SVs | 10=ONLY 3 USABLE SVs | 11=BAD INTEGRITY | 12=NO VEL AVAIL | 13=UNUSABLE FIX
USLAB000044 Global Positioning System (GPS-2) Ops Status 0=DOING POSITION FIXES | 1=SV TIMING | 2=APPROXIMATE TIMING | 3=GPS TIME | 4=NEED INITIALIZATION | 5=GDOP NEEDED | 6=BAD TIMING | 7=NO USABLE SV | 8=ONLY 1 USABLE SVs | 9=ONLY 2 USABLE SVs | 10=ONLY 3 USABLE SVs | 11=BAD INTEGRITY | 12=NO VEL AVAIL | 13=UNUSABLE FIX
USLAB000045 Spin Motor Spin Bearing Temperature - Control Moment Gyroscope (CMG) 1 (deg C) {0:f1}
USLAB000046 Spin Motor Spin Bearing Temperature - Control Moment Gyroscope (CMG) 2 (deg C) {0:f1}
USLAB000047 Spin Motor Spin Bearing Temperature - Control Moment Gyroscope (CMG) 3 (deg C) {0:f1}
USLAB000048 Spin Motor Spin Bearing Temperature - Control Moment Gyroscope (CMG) 4 (deg C) {0:f1}
USLAB000049 Hall Resolver Spin Bearing Temperature - Control Moment Gyroscope (CMG) 1 (deg C) {0:f1}
USLAB000050 Hall Resolver Spin Bearing Temperature - Control Moment Gyroscope (CMG) 2 (deg C) {0:f1}
USLAB000051 Hall Resolver Spin Bearing Temperature - Control Moment Gyroscope (CMG) 3 (deg C) {0:f1}
USLAB000052 Hall Resolver Spin Bearing Temperature - Control Moment Gyroscope (CMG) 4 (deg C) {0:f1}
Z1000001 Control Moment Gyroscope (CMG)-1 Vibration (g) {0:f2}
Z1000002 Control Moment Gyroscope (CMG)-2 Vibration (g) {0:f2}
Z1000003 Control Moment Gyroscope (CMG)-3 Vibration (g) {0:f2}
Z1000004 Control Moment Gyroscope (CMG)-4 Vibration (g) {0:f2}
Z1000005 Control Moment Gyroscope (CMG)-1 Spin Motor Current (amps) {0:f2}
Z1000006 Control Moment Gyroscope (CMG)-2 Spin Motor Current (amps) {0:f2}
Z1000007 Control Moment Gyroscope (CMG)-3 Spin Motor Current (amps) {0:f2}
Z1000008 Control Moment Gyroscope (CMG)-4 Spin Motor Current (amps) {0:f2}
Z1000009 Control Moment Gyroscope (CMG) 1 Wheel Speed (rpm) {0:d0}
Z1000010 Control Moment Gyroscope (CMG) 2 Wheel Speed (rpm) {0:d0}
Z1000011 Control Moment Gyroscope (CMG) 3 Wheel Speed (rpm) {0:d0}
Z1000012 Control Moment Gyroscope (CMG) 4 Wheel Speed (rpm) {0:d0}

CDH

Key Description Property Type
AIRLOCK000058 Airlock Multiplexer/Demultiplexer (MDM) on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE1000001 Node 1 Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE1000002 Node 1 Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE2000004 Node 2 Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE2000005 Node 2 Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE3000014 Hub Control Zone (HCZ) Multiplexer/Demultiplexer 2 (MDM) on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE3000015 Node 3 Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE3000016 Hub Control Zone (HCZ) Multiplexer/Demultiplexer 1 (MDM) on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
NODE3000020 Node 3 Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
P1000006 P1 Truss Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
P1000008 Port Thermal Radiator (STR) Multiplexer/Demultiplexer (MDM) on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
P1000009 P1 Truss Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
P3000001 P3 Truss Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
P3000002 P3 Truss Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
P4000003 Photovolatic Control Unit (PVCU) - Solar Array - 2A Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
P4000006 Photovolatic Control Unit (PVCU) - Solar Array - 4A Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
P6000003 Photovolatic Control Unit (PVCU) - Solar Array - 4B Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
P6000006 Photovolatic Control Unit (PVCU) - Solar Array - 2B Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
S0000010 External Control Zone Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S0000011 S0 Truss Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S0000012 External Control Zone Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S0000013 S0 Truss Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S1000006 Starboard Thermal Radiator (STR) Multiplexer/Demultiplexer (MDM) on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S1000007 S1 Truss Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S1000008 S1 Truss Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S3000001 S3 Truss Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S3000002 S3 Truss Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S4000003 Photovolatic Control Unit (PVCU) - Solar Array - 1A Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
S4000006 Photovolatic Control Unit (PVCU) - Solar Array - 3A Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
S6000003 Photovolatic Control Unit (PVCU) - Solar Array - 3B Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
S6000006 Photovolatic Control Unit (PVCU) - Solar Array - 1B Multiplexer/Demultiplexer (MDM) 120 Volt On-Off Status 0=Not Enabled | 1=Enabled
USLAB000066 Command and Control (C&C) Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000067 Command and Control (C&C) Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000068 Command and Control (C&C) Multiplexer/Demultiplexer (MDM) 3 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000069 Internal Control Zone Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000070 Internal Control Zone Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000071 Payload (PL) Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000072 Payload (PL) Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000073 Guidance, Navigation and Control (GNC) Multiplexer/Demultiplexer 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000074 Guidance, Navigation and Control (GNC) Multiplexer/Demultiplexer 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000075 Power Management Controller Unit (PMCU) 1 Multiplexer/Demultiplexer 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000076 Power Management Controller Unit (PMCU) 2 Multiplexer/Demultiplexer 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000077 US Lab Multiplexer/Demultiplexer (MDM) 1 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000078 US Lab Multiplexer/Demultiplexer (MDM) 2 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000079 US Lab Multiplexer/Demultiplexer (MDM) 3 on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000080 Permanent Multipurpose Module - System Power voltage status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed

CATO

Key Description Property Type
P1000004 S-Band Radio Frequency Group (RFG 2) Azimuth Gimbal Position {0:f2}
P1000005 S-Band Radio Frequency Group (RFG 2) Elevation Gimbal Position {0:f2}
P1000007 S-Band Radio Frequency Group (RFG 2), on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
S1000004 S-Band Radio Frequency Group (RFG 1) Azimuth Gimbal Position {0:f2}
S1000009 S-Band Radio Frequency Group (RFG 1), on-off status 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000088 Ku-Band Video Downlink Channel 1 Activity 0=INACTIVE | 1=ACTIVE
USLAB000089 Ku-Band Video Downlink Channel 2 Activity 0=INACTIVE | 1=ACTIVE
USLAB000090 Ku-Band Video Downlink Channel 3 Activity 0=INACTIVE | 1=ACTIVE
USLAB000091 Ku-Band Video Downlink Channel 4 Activity 0=INACTIVE | 1=ACTIVE
USLAB000092 Active String of S-Band 1=String 1 | 2=String 2
USLAB000093 Internal Audio Controller (IAC) - IAC-1 Active/Backup Indication 0=Backup | 1=Active
USLAB000094 Internal Audio Controller (IAC) - IAC-2 Active/Backup Indication 0=Backup | 1=Active
USLAB000095 Video Source Routed to Downlink 1 0= - | 1=S3AFT | 2=S1UPOB | 3=SCU1 Mux | 4=S1LOOB | 5=JPM a | 6=JPM b | 7=S1UPIB | 8=S1LOIB | 9=COL 1 | 10=COL 2 | 11=P1UPIB | 12=SCU2 Mux | 13=NOD3S | 14=P1LOIB | 15=SCU1 Test | 16=WETA112 | 17=ORB1 | 18=ORB2 | 19=P1LOOB | 20=SCU2 Test | 21=P3AFT | 22=Payload Rack | 23=VTR1 | 24=VTR2 | 25=NOD2LO | 26=WETA115 | 28=LAB S | 31=POA PL3 | 32=POA | 33=SPDMS1 | 34=SPDMS2 | 35=MBS CLPA | 36=SPDMLEE | 37=MAST | 40=BLEE | 43=BELB | 48=TELB | 50=MSS PL3 | 51=TLEE | 52=Lab AVU1 | 53=Lab AVU2 | 54=Cup AVU1 | 55=Cup AVU2 | 56=OTCM1 | 57=BODY1 | 58=OTCM2 | 59=BODY2 | 60=SSRMS PL1 | 61=SSRMS PL2 | 62=SSRMS PL3 | 63=MSS PL1 | 64=MSS PL2 | 65=LAB1D3 | 66=LAB1P2 | 67=LAB1P4 | 68=LABCAM | 69=LAB1O5 | 70=LAB1O4 | 71=LAB1O3 | 72=LAB1O2 | 73=LAB1O1 | 74=LAB1S1 | 75=LAB1S2 | 76=LAB1S3 | 77=A/L CAM | 78=LAB1S4 | 79=N1 CAM | 80=N3 CAM
USLAB000096 Video Source Routed to Downlink 2 0= - | 1=S3AFT | 2=S1UPOB | 3=SCU1 Mux | 4=S1LOOB | 5=JPM a | 6=JPM b | 7=S1UPIB | 8=S1LOIB | 9=COL 1 | 10=COL 2 | 11=P1UPIB | 12=SCU2 Mux | 13=NOD3S | 14=P1LOIB | 15=SCU1 Test | 16=WETA112 | 17=ORB1 | 18=ORB2 | 19=P1LOOB | 20=SCU2 Test | 21=P3AFT | 22=Payload Rack | 23=VTR1 | 24=VTR2 | 25=NOD2LO | 26=WETA115 | 28=LAB S | 31=POA PL3 | 32=POA | 33=SPDMS1 | 34=SPDMS2 | 35=MBS CLPA | 36=SPDMLEE | 37=MAST | 40=BLEE | 43=BELB | 48=TELB | 50=MSS PL3 | 51=TLEE | 52=Lab AVU1 | 53=Lab AVU2 | 54=Cup AVU1 | 55=Cup AVU2 | 56=OTCM1 | 57=BODY1 | 58=OTCM2 | 59=BODY2 | 60=SSRMS PL1 | 61=SSRMS PL2 | 62=SSRMS PL3 | 63=MSS PL1 | 64=MSS PL2 | 65=LAB1D3 | 66=LAB1P2 | 67=LAB1P4 | 68=LABCAM | 69=LAB1O5 | 70=LAB1O4 | 71=LAB1O3 | 72=LAB1O2 | 73=LAB1O1 | 74=LAB1S1 | 75=LAB1S2 | 76=LAB1S3 | 77=A/L CAM | 78=LAB1S4 | 79=N1 CAM | 80=N3 CAM
USLAB000097 Video Source Routed to Downlink 3 0= - | 1=S3AFT | 2=S1UPOB | 3=SCU1 Mux | 4=S1LOOB | 5=JPM a | 6=JPM b | 7=S1UPIB | 8=S1LOIB | 9=COL 1 | 10=COL 2 | 11=P1UPIB | 12=SCU2 Mux | 13=NOD3S | 14=P1LOIB | 15=SCU1 Test | 16=WETA112 | 17=ORB1 | 18=ORB2 | 19=P1LOOB | 20=SCU2 Test | 21=P3AFT | 22=Payload Rack | 23=VTR1 | 24=VTR2 | 25=NOD2LO | 26=WETA115 | 28=LAB S | 31=POA PL3 | 32=POA | 33=SPDMS1 | 34=SPDMS2 | 35=MBS CLPA | 36=SPDMLEE | 37=MAST | 40=BLEE | 43=BELB | 48=TELB | 50=MSS PL3 | 51=TLEE | 52=Lab AVU1 | 53=Lab AVU2 | 54=Cup AVU1 | 55=Cup AVU2 | 56=OTCM1 | 57=BODY1 | 58=OTCM2 | 59=BODY2 | 60=SSRMS PL1 | 61=SSRMS PL2 | 62=SSRMS PL3 | 63=MSS PL1 | 64=MSS PL2 | 65=LAB1D3 | 66=LAB1P2 | 67=LAB1P4 | 68=LABCAM | 69=LAB1O5 | 70=LAB1O4 | 71=LAB1O3 | 72=LAB1O2 | 73=LAB1O1 | 74=LAB1S1 | 75=LAB1S2 | 76=LAB1S3 | 77=A/L CAM | 78=LAB1S4 | 79=N1 CAM | 80=N3 CAM
USLAB000098 Video Source Routed to Downlink 4 0= - | 1=S3AFT | 2=S1UPOB | 3=SCU1 Mux | 4=S1LOOB | 5=JPM a | 6=JPM b | 7=S1UPIB | 8=S1LOIB | 9=COL 1 | 10=COL 2 | 11=P1UPIB | 12=SCU2 Mux | 13=NOD3S | 14=P1LOIB | 15=SCU1 Test | 16=WETA112 | 17=ORB1 | 18=ORB2 | 19=P1LOOB | 20=SCU2 Test | 21=P3AFT | 22=Payload Rack | 23=VTR1 | 24=VTR2 | 25=NOD2LO | 26=WETA115 | 28=LAB S | 31=POA PL3 | 32=POA | 33=SPDMS1 | 34=SPDMS2 | 35=MBS CLPA | 36=SPDMLEE | 37=MAST | 40=BLEE | 43=BELB | 48=TELB | 50=MSS PL3 | 51=TLEE | 52=Lab AVU1 | 53=Lab AVU2 | 54=Cup AVU1 | 55=Cup AVU2 | 56=OTCM1 | 57=BODY1 | 58=OTCM2 | 59=BODY2 | 60=SSRMS PL1 | 61=SSRMS PL2 | 62=SSRMS PL3 | 63=MSS PL1 | 64=MSS PL2 | 65=LAB1D3 | 66=LAB1P2 | 67=LAB1P4 | 68=LABCAM | 69=LAB1O5 | 70=LAB1O4 | 71=LAB1O3 | 72=LAB1O2 | 73=LAB1O1 | 74=LAB1S1 | 75=LAB1S2 | 76=LAB1S3 | 77=A/L CAM | 78=LAB1S4 | 79=N1 CAM | 80=N3 CAM
USLAB000099 Space-To-Space Radio (UHF) 1 Power 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000100 Space-To-Space Radio (UHF) 2 Power 0=Off-Ok | 1=Not-Off Ok | 3=Not-Off Failed
USLAB000101 Space-To-Space Radio Frame Sync Lock 0=Frame Sync unlocked | 1=Frame Sync locked
Z1000013 Ku-Band Transmit 0=RESET | 1=NORMAL
Z1000014 Ku-Band SGANT Elevation Position {0:f2}
Z1000015 Ku-Band SGANT Cross-Elevation Position {0:f2}

CSA

Key Description Property Type
CSAMT000001 MSS MT Position Float Position, centimeters from 0
CSAMT000001 MSS MT Utility Port ID (which Worksite MT is connected to, WS1 though WS8) 1=WS1 | 2=WS2 | 3=WS3 | 4=WS4 | 5=WS5 | 6=WS6 | 7=WS7 | 8=WS8
CSASSRMS001 MSS EDCD SSRMS Base Location ?
CSASSRMS002 MSS EDCD SSRMS Base Location 1=Lab | 2=Node3 | 4=Node2 | 7=MBS PDGF 1 | 8=MBS PDGF 2 | 11=MBS PDGF 3 | 13=MBS PDGF 4 | 14=FGB | 16=POA | 19=SSRMS Tip LEE | 63=Undefined
CSASSRMS003 MSS EDCD SSRMS Operating Base (Which LEE is Base) 0=Lee A | 5=Lee B
CSASSRMS004 SSRMS SR Measured Joint Position Angle
CSASSRMS005 SSRMS SY Measured Joint Position Angle
CSASSRMS006 SSRMS SP Measured Joint Position Angle
CSASSRMS007 SSRMS EP Measured Joint Position Angle
CSASSRMS008 SSRMS WP Measured Joint Position Angle
CSASSRMS009 SSRMS WY Measured Joint Position Angle
CSASSRMS010 SSRMS WR Measured Joint Position Angle
CSASSRMS011 MSS OCS Payload Status SSRMS Tip LEE 0=Released | 1=Captive | 2=Captured
CSASPDM0001 MSS OCS Base Location SPDM ?
CSASPDM0002 MSS OCS Base Location SPDM 1=Lab | 2=Node3 | 4=Node2 | 7=MBS PDGF 1 | 8=MBS PDGF 2 | 11=MBS PDGF 3 | 13=MBS PDGF 4 | 14=FGB | 16=POA | 19=SSRMS Tip LEE | 63=Undefined
CSASPDM0003 MSS OCS SPDM 1 SR Measured Joint Position Angle
CSASPDM0004 MSS OCS SPDM 1 SY Measured Joint Position Angle
CSASPDM0005 MSS OCS SPDM 1 SP Measured Joint Position Angle
CSASPDM0006 MSS OCS SPDM 1 EP Measured Joint Position Angle
CSASPDM0007 MSS OCS SPDM 1 WP Measured Joint Position Angle
CSASPDM0008 MSS OCS SPDM 1 WY Measured Joint Position Angle
CSASPDM0009 MSS OCS SPDM 1 WR Measured Joint Position Angle
CSASPDM0010 MSS Payload Status OCS SPDM Arm 1 OTCM 0=Released | 1=Captive | 2=Captured
CSASPDM0011 MSS OCS SPDM 2 SR Measured Joint Position Angle
CSASPDM0012 MSS OCS SPDM 2 SY Measured Joint Position Angle
CSASPDM0013 MSS OCS SPDM 2 SP Measured Joint Position Angle
CSASPDM0014 MSS OCS SPDM 2 EP Measured Joint Position Angle
CSASPDM0015 MSS OCS SPDM 2 WP Measured Joint Position Angle
CSASPDM0016 MSS OCS SPDM 2 WY Measured Joint Position Angle
CSASPDM0017 MSS OCS SPDM 2 WR Measured Joint Position Angle
CSASPDM0018 MSS Payload Status OCS SPDM Arm 2 OTCM? ?
CSASPDM0019 MSS Payload Status OCS SPDM Arm 2 OTCM 0=Released | 1=Captive | 2=Captured
CSASPDM0020 MSS OCS SPDM Body Roll Joint Position Angle
CSASPDM0021 MSS Payload Status OCS SPDM Body? ?
CSASPDM0022 MSS Payload Status OCS SPDM Body 0=Released | 1=Captive | 2=Captured
CSAMBS00001 MSS OCS Payload Status MBS MCAS? ?
CSAMBS00002 MSS OCS Payload Status MBS MCAS 0=Released | 1=Captured
CSAMBA00003 MSS OCS Payload Status MBS POA? ?
CSAMBA00004 MSS OCS Payload Status MBS POA 0=Released | 1=Captive | 2=Captured

EVA

Key Description Property Type
AIRLOCK000001 Supplies power through the Umbilical Interface Assembly (UIA) to the spacesuits (EMU 1), Voltage {0:f2}
AIRLOCK000002 Supplies power through the Umbilical Interface Assembly (UIA) to the spacesuits (EMU 1), Current {0:f2}
AIRLOCK000003 Supplies power through the Umbilical Interface Assembly (UIA) to the spacesuits (EMU 2), Voltage {0:f2}
AIRLOCK000004 Supplies power through the Umbilical Interface Assembly (UIA) to the spacesuits (EMU 2), Current {0:f2}
AIRLOCK000005 In-flight Refill Unit (IRU), Voltage {0:f2}
AIRLOCK000006 In-flight Refill Unit (IRU), Current {0:f2}
AIRLOCK000007 Supplies power to the spacesuits (EVA Mobility Unit, EMU 1), Voltage {0:f2}
AIRLOCK000008 Supplies power to the spacesuits (EVA Mobility Unit, EMU 1), Current {0:f2}
AIRLOCK000009 Supplies power to the spacesuits (EVA Mobility Unit, EMU 2), Voltage {0:f2}
AIRLOCK000010 Supplies power to the spacesuits (EVA Mobility Unit, EMU 2), Current {0:f2}
AIRLOCK000011 Battery Charger Assembly (BCA) 1 Voltage {0:f2}
AIRLOCK000012 Battery Charger Assembly (BCA) 1 Current {0:f2}
AIRLOCK000013 Battery Charger Assembly (BCA) 2 Voltage {0:f2}
AIRLOCK000014 Battery Charger Assembly (BCA) 2 Current {0:f2}
AIRLOCK000015 Battery Charger Assembly (BCA) 3 Voltage {0:f2}
AIRLOCK000016 Battery Charger Assembly (BCA) 3 Current {0:f2}
AIRLOCK000017 Battery Charger Assembly (BCA) 4 Voltage {0:f2}
AIRLOCK000018 Battery Charger Assembly (BCA) 4 Current {0:f2}
AIRLOCK000019 Battery Charger Assembly (BCA) 1 Status 0=Normal | 1=No Data | 2=Missing Data | 3=Extra Data
AIRLOCK000020 Battery Charger Assembly (BCA) 2 Status 0=Normal | 1=No Data | 2=Missing Data | 3=Extra Data
AIRLOCK000021 Battery Charger Assembly (BCA) 3 Status 0=Normal | 1=No Data | 2=Missing Data | 3=Extra Data
AIRLOCK000022 Battery Charger Assembly (BCA) 4 Status 0=Normal | 1=No Data | 2=Missing Data | 3=Extra Data
AIRLOCK000023 Battery Charger Assembly (BCA) 1 Channel 1 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000024 Battery Charger Assembly (BCA) 1 Channel 2 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000025 Battery Charger Assembly (BCA) 1 Channel 3 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000026 Battery Charger Assembly (BCA) 1 Channel 4 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000027 Battery Charger Assembly (BCA) 1 Channel 5 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000028 Battery Charger Assembly (BCA) 1 Channel 6 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000029 Battery Charger Assembly (BCA) 2 Channel 1 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000030 Battery Charger Assembly (BCA) 2 Channel 2 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000031 Battery Charger Assembly (BCA) 2 Channel 3 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000032 Battery Charger Assembly (BCA) 2 Channel 4 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000033 Battery Charger Assembly (BCA) 2 Channel 5 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000034 Battery Charger Assembly (BCA) 2 Channel 6 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000035 Battery Charger Assembly (BCA) 3 Channel 1 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000036 Battery Charger Assembly (BCA) 3 Channel 2 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000037 Battery Charger Assembly (BCA) 3 Channel 3 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to a time-out error | 14=Task terminated due to an external-temperature error | 15=Discharge | 16=Wait on Discharge | 17=Wait on Charge
AIRLOCK000038 Battery Charger Assembly (BCA) 3 Channel 4 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000039 Battery Charger Assembly (BCA) 3 Channel 5 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000040 Battery Charger Assembly (BCA) 3 Channel 6 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000041 Battery Charger Assembly (BCA) 4 Channel 1 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000042 Battery Charger Assembly (BCA) 4 Channel 2 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000043 Battery Charger Assembly (BCA) 4 Channel 3 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000044 Battery Charger Assembly (BCA) 4 Channel 4 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000045 Battery Charger Assembly (BCA) 4 Channel 5 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000046 Battery Charger Assembly (BCA) 4 Channel 6 Status 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK
AIRLOCK000047 Pumps atmosphere from Airlock into Node one during depress, voltage status. 0=Off-Ok | 1=Not-Off Ok | 2=Not-Off Failed\
AIRLOCK000048 Pumps atmosphere from Airlock into Node one during depress, switch status. 0=No History - a charge has not been initiated yet | 1=Presently charging | 2=Task completed normally | 3=Task terminated due to stop switch being toggled | 4=Task terminated due to an open circuit error | 5=Task terminated due to Wrong Batt or Hi-imp | 6=Task terminated due to an over-temperature error | 7=Amp-hour capacity test result OK | 8=Amp-hour capacity test error | 9=Task terminated due to low charge slope error | 10=Task terminated due to power error | 11=Task terminated due to reverse-polarity error | 12=Task terminated due to a short-circuit error | 13=Task terminated due to### AIRLOCK

ETHOS

AIRLOCK and NODE

Key Description Property Type
AIRLOCK000049 Crewlock Pressure {0:f2}
AIRLOCK000050 Hi P O2 Supply valve position 0=CLOSED | 1=OPEN | 2=IN-TRANSIT | 3=FAILED
AIRLOCK000051 Lo P O2 Supply Valve position 0=CLOSED | 1=OPEN | 2=IN-TRANSIT | 3=FAILED
AIRLOCK000052 N2 Supply Valve position 0=CLOSED | 1=OPEN | 2=IN-TRANSIT | 3=FAILED
AIRLOCK000053 Airlock Air Conditioner State 0=RESET | 1=DRAIN | 2=DRYOUT | 3=EIB OFF | 4=OFF | 5=ON | 6=STARTUP | 7=TEST
AIRLOCK000054 Airlock Pressure {0:f2}
AIRLOCK000055 Airlock Hi P O2 Tank Pressure {0:f1}
AIRLOCK000056 Airlock Lo P O2 Tank Pressure {0:f1}
AIRLOCK000057 Airlock N2 Tank Pressure {0:f1}
NODE2000001 Coolant water quantity (Node 2), MT {0:f1}
NODE2000002 Coolant water quantity (Node 2), LT {0:f1}
NODE2000003 Node 2 Air Conditioner State 0=RESET | 1=DRAIN | 2=DRYOUT | 3=EIB OFF | 4=OFF | 5=ON | 6=STARTUP | 7=TEST
NODE2000006 Air Cooling Fluid Temp (Node 2) {0:f1}
NODE2000007 Avionics Cooling Fluid Temp (Node 2) {0:f1}
NODE3000001 Node 3 ppO2 {0:f2}
NODE3000002 Node 3 ppN2 {0:f2}
NODE3000003 Node 3 ppCO2 {0:f2}
NODE3000004 Urine Processor State 2=STOP | 4=SHUTDOWN | 8=MAINTENANCE | 16=NORMAL | 32=STANDBY | 64=IDLE | 128=SYSTEM INITIALIZED
NODE3000005 Urine Tank Qty {0:f1}
NODE3000006 Water Processor State 1=STOP | 2=SHUTDOWN | 3=STANDBY | 4=PROCESS | 5=HOT SERVICE | 6=FLUSH | 7=WARM SHUTDOWN
NODE3000007 Water Processor Step 0=NONE | 1=VENT | 2=HEATUP | 3=PURGE | 4=FLOW | 5=TEST | 6=TEST_SV_1 | 7=TEST_SV_2 | 8=SERVICE
NODE3000008 Waste Water Tank Qty {0:f1}
NODE3000009 Clean Water Tank Qty {0:f1}
NODE3000010 Oxygen Generator State 1=PROCESS | 2=STANDBY | 3=SHUTDOWN | 4=STOP | 5=VENT_DOME | 6=INERT_DOME | 7=FAST_SHUTDOWN | 8=N2_PURGE_SHUTDOWN
NODE3000011 O2 Production rate {0:f2}
NODE3000012 Avionics Cooling Fluid Temp (Node 3) {0:f1}
NODE3000013 Air Cooling Fluid Temp (Node 3) {0:f2}
NODE3000017 Coolant water quantity (Node 3) {0:f1}
NODE3000018 Node 3 Air Conditioner State 0=RESET | 1=DRAIN | 2=DRYOUT | 3=EIB OFF | 4=OFF | 5=ON | 6=STARTUP | 7=TEST
NODE3000019 Coolant water quantity (Node 3) {0:f1}
USLAB000053 Lab ppO2 {0:f2}
USLAB000054 Lab ppN2 {0:f2}
USLAB000055 Lab ppCO2 {0:f2}
USLAB000056 Coolant water quantity, LT (Lab) {0:f1}
USLAB000057 Coolant water quantity, MT (Lab) {0:f1}
USLAB000058 Cabin pressure {0:f2}
USLAB000059 Cabin temperature {0:f1}
USLAB000060 Avionics Cooling Fluid Temp (Lab) {0:f1}
USLAB000061 Air Cooling Fluid Temp (Lab) {0:f2}
USLAB000062 Vacuum Resource System Valve Position 0=FAIL | 1=OPEN | 2=CLSD | 3=TRNS
USLAB000063 Vacuum Exhaust System Valve Position 0=FAIL | 1=OPEN | 2=CLSD | 3=TRNS
USLAB000064 Lab Port Air Conditioner State 0=RESET | 1=DRAIN | 2=DRYOUT | 3=EIB OFF | 4=OFF | 5=ON | 6=STARTUP | 7=TEST
USLAB000065 Lab Starboard Air Conditioner State 0=RESET | 1=DRAIN | 2=DRYOUT | 3=EIB OFF | 4=OFF | 5=ON | 6=STARTUP | 7=TEST

ODIN

Key Description Property Type
USLAB000082 Standard Command Counter - Count of standard commands received by the ISS Command and Control Computer {0:d0}
USLAB000083 Data Load Command Counter - Count of data load commands received by the ISS Command and Control Computer {0:d0}
USLAB000084 ISS Command and Control Multiplexer/Demultiplexer Onboard Time (course) %sT
USLAB000085 ISS Command and Control Multiplexer/Demultiplexer Onboard Time (fine) {0:f7}
USLAB000087 # Laptops active and connected to the Primary Command and Control (C&C) Multiplexer/Demultiplexer (MDM) {0:d0}

SPARTAN

SPARTAN

Key Description Property Type
P1000001 Loop B Pump Flowrate (kg/hr) {0:f1}
P1000002 Loop B PM Out Press (kPa) {0:f1}
P1000003 Loop B PM Out Temp (deg C) {0:f1}
P4000001 Photovolatic Control Unit (PVCU) - Solar Array - 2A - Drive Voltage {0:f1}
P4000002 Photovolatic Control Unit (PVCU) - Solar Array - 2A - Drive Current {0:f2}
P4000004 Photovolatic Control Unit (PVCU) - Solar Array - 4A - Drive Voltage {0:f1}
P4000005 Photovolatic Control Unit (PVCU) - Solar Array - 4A - Drive Current {0:f2}
P4000007 Photovolatic Control Unit (PVCU) - Solar Array - 2A - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}
P4000008 Photovolatic Control Unit (PVCU) - Solar Array - 4A - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}
P6000001 Photovolatic Control Unit (PVCU) - Solar Array - 4B - Drive Voltage {0:f1}
P6000002 Photovolatic Control Unit (PVCU) - Solar Array - 4B - Drive Current {0:f2}
P6000004 Photovolatic Control Unit (PVCU) - Solar Array - 2B - Drive Voltage {0:f1}
P6000005 Photovolatic Control Unit (PVCU) - Solar Array - 2B - Drive Current {0:f2}
P6000007 Photovolatic Control Unit (PVCU) - Solar Array - 4B - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}
P6000008 Photovolatic Control Unit (PVCU) - Solar Array - 2B - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}
S1000001 Loop A Pump Flowrate (kg/hr) {0:f1}
S1000002 Loop A PM Out Press (kPa) {0:f1}
S1000003 Loop A PM Out Temp (deg C) {0:f1}
S4000001 Photovolatic Control Unit (PVCU) - Solar Array - 1A - Drive Voltage {0:f1}
S4000002 Photovolatic Control Unit (PVCU) - Solar Array - 1A - Drive Current {0:f2}
S4000004 Photovolatic Control Unit (PVCU) - Solar Array - 3B - Drive Voltage {0:f1}
S4000005 Photovolatic Control Unit (PVCU) - Solar Array - 3B - Drive Current {0:f2}
S4000007 Photovolatic Control Unit (PVCU) - Solar Array - 1A - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}
S4000008 Photovolatic Control Unit (PVCU) - Solar Array - 3A - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}
S6000001 Photovolatic Control Unit (PVCU) - Solar Array - 3B - Drive Voltage {0:f1}
S6000002 Photovolatic Control Unit (PVCU) - Solar Array - 3B - Drive Current {0:f2}
S6000004 Photovolatic Control Unit (PVCU) - Solar Array - 1B - Drive Voltage {0:f1}
S6000005 Photovolatic Control Unit (PVCU) - Solar Array - 1B - Drive Current {0:f2}
S6000007 Photovolatic Control Unit (PVCU) - Solar Array - 3B - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}
S6000008 Photovolatic Control Unit (PVCU) - Solar Array - 1B - Beta Gimble Assembly (BGA) Position (degrees) {0:f1}

VVO

Key Description Property Type
RUSSEG000001 Russian Segment Station Mode - Service Module (SM) 1=Crew Rescue | 2=Survival | 3=Reboost | 4=Proximity Operations | 5=EVA | 6=Microgravity | 7=Standard
RUSSEG000002 First Kurs Equipment Kit Operating 0=Undetermined State | 1=SM KURS Equipment Set1 Operating-RS
RUSSEG000003 Second Kurs Equipment Kit Operating 0=Undetermined State | 1=SM KURS Equipment Set2 Operating-RS
RUSSEG000004 Service Module Kurs P1, P2 Failure - Russian Segment 0=Undeterminated State | 1=SM KURS P1, P2 Failure-RS
RUSSEG000005 Distance from Service Module (SM) Kurs (Range) {0:d0}
RUSSEG000006 Rate from Service Module (SM) Kurs (Range Rate) {0:f2}
RUSSEG000007 Service Module (SM) Kurs-P Test Mode - Russian Segment 0=Undetermined State | 1=SM KURS-P Test Mode-RS
RUSSEG000008 Service Module (SM) Kurs-P "Capture" Signal Availability 0=Undetermined State | 1=SM KURS-P Capture Signal -RS
RUSSEG000009 Service Module (SM) Kurs-P Target Acquisition Signal - Russian Segment 0=Undetermined State | 1=SM KURS-P Target Acquisition Signal-RS
RUSSEG000010 Service Module (SM) Kurs-P Functional Mode Signal - Russian Segment 0=Undetermined State | 1=SM KURS-P Functional Mode Signal-RS
RUSSEG000011 Service Module (SM) Kurs-P Standby Mode - Russian Segment 0=Undetermined State | 1=SM KURS-P In Standby Mode-RS
RUSSEG000012 Service Module Docking Flag 0=Undetermined State | 1=SM Docking Flag-RS
RUSSEG000013 Service Module (SM) Forward Docking Port Engaged 0=Undetermined State | 1=SM Docking Port Engaged from Xfer Side-RS
RUSSEG000014 Service Module (SM) Aft Docking Port Engaged 0=Undetermined State | 1=SM Docking Port Engaged from Instr Compartment Side-RS
RUSSEG000015 Service Module (SM) Nadir (Down-looking) Docking Port Engaged - Along Y-Axis 0=Undetermined State | 1=SM Docking Port Engaged Below (along SM -Y Axis)-RS
RUSSEG000016 Functional Cargo Block (FGB) Nadir (Down-looking) Docking Port Engaged - Along Y-Axis 0=Undetermined State | 1=FGB Bottom Docking Port Engaged (along SM -Y Axis)-RS
RUSSEG000017 Service Module (SM) Nadir (Down-looking) Universal Docking Module (UDM) Docking Port Engaged - Along Y-Axis 0=Undetermined State | 1=SM Bottom UDM Docking Port Engaged (along SM -Y Axis)-RS
RUSSEG000018 Mini Research Module (MRM) 1 Docking Port Engaged - Russian Segment 0=Undetermined State | 1=MRM1 Docking Port Engaged-RS
RUSSEG000019 Mini Research Module (MRM) 2 Docking Port Engaged - Russian Segment 0=Undetermined State | 1=MRM2 Docking Port Engaged-RS
RUSSEG000020 Service Module - Docked Vehicle Hooks Closed - Russian Segment 0=Undetermined State | 1=Docked Vehicle Hooks Closed-RS
RUSSEG000021 Service Module - Russian Guidance, Navigation, and Control - Active Attitude Mode - Russian Segment 0=Inertial Attitude | 1=LVLH SM | 2=Solar Orientation | 3=Current LVLH | 4=Current Inertial Attitude | 5=Damping | 6=TEA | 7=X-POP
RUSSEG000022 Service Module - Russian Guidance, Navigation, and Control - Motion Control - Russian Segment 0=Undetermined State | 1=SM SUDN Controls the Motion (RS master)-RS
RUSSEG000023 Service Module - Russian Guidance, Navigation, and Control - Prepared to Free Drift Mode Transition - Russian Segment 0=Undetermined State | 1=SM SUDN Prepared to Free Drift Mode Transition-RS
RUSSEG000024 Service Module - Russian Guidance, Navigation, and Control - Thruster Operation Mode Terminated - Russian Segment 0=Pre-Starting Procedure Or Thruster Operation Readiness | 1=Thruster Operation Mode is Terminated
S0000005 Solar Alpha Rotary Joint (SARJ) Port Joint Angle Commanded Position (degrees) {0:f2}
S0000006 External Thermal Control System (ETCS) - Thermal Radiator Rotating Joint (TRRJ) - Loop B - Software mode 1=STANDBY | 2=RESTART | 3=CHECKOUT | 4=DIRECTED_POSITION | 5=AUTOTRACK | 6=BLIND | 7=SHUTDOWN | 8=SWITCHOVER
S0000007 External Thermal Control System (ETCS) - Thermal Radiator Rotating Joint (TRRJ) - Loop A - Software mode 1=STANDBY | 2=RESTART | 3=CHECKOUT | 4=DIRECTED_POSITION | 5=AUTOTRACK | 6=BLIND | 7=SHUTDOWN | 8=SWITCHOVER
S0000008 External Primary Solar Alpha Rotary Joint (SARJ) Port Mode 1=STANDBY | 2=RESTART | 3=CHECKOUT | 4=DIRECTED_POSITION | 5=AUTOTRACK | 6=BLIND | 7=SHUTDOWN | 8=SWITCHOVER
S0000009 External Primary Solar Alpha Rotary Joint (SARJ) Starboard Mode 1=STANDBY | 2=RESTART | 3=CHECKOUT | 4=DIRECTED_POSITION | 5=AUTOTRACK | 6=BLIND | 7=SHUTDOWN | 8=SWITCHOVER
USLAB000081 Attitude Maneuver In Progress status 0=FALSE | 1=TRUE

ADCO/TOPO

Key Description Property Type
USLAB000032 US Guidance, Navigation and Control (GNC) J2000 Propagated State Vector - X (km) {0:f9}
USLAB000033 US Guidance, Navigation and Control (GNC) J2000 Propagated State Vector - Y (km) {0:f9}
USLAB000034 US Guidance, Navigation and Control (GNC) J2000 Propagated State Vector - Z (km) {0:f9}
USLAB000035 US Guidance, Navigation and Control (GNC) J2000 Propagated State Vector - X (m/s) {0:f9}
USLAB000036 US Guidance, Navigation and Control (GNC) J2000 Propagated State Vector - Y (m/s) {0:f9}
USLAB000037 US Guidance, Navigation and Control (GNC) J2000 Propagated State Vector - Z (m/s) {0:f9}

ADCO/VVO

Key Description Property Type
RUSSEG000025 Service Module - Russian Guidance, Navigation, and Control - Current Dynamic Mode - Russian Segment 0=0 - Reserv | 1=1 - Thrusters | 2=2 - Gyrodines | 3=3 - Gyrodines with Desaturation on American Method | 4=4 - Gyrodines with Desaturation on Russian Method | 5=5 - Translational Thrusters Operating | 6=6 - Thrusters help CMG (desaturate CMG) | 7=7 - Free Drift Mode
USLAB000010 Control Moment Gyroscope (CMG) Momentum Percentage (%) {0:f2}
USLAB000012 US Guidance, Navigation and Control (GNC) Mode 0=Default | 1=WAIT | 2=RESERVED | 3=STANDBY | 4=CMG ATTITUDE CONTROL | 5=CMG/THRUSTER ASSIST ATTITUDE CONTROL | 6=USER DATA GENERATION | 7=FREEDRIFT

CATO/VVO

Key Description Property Type
S1000005 S-Band Radio Frequency Group (RFG 1) Elevation Gimbal Position {0:f2}

ODIN/VVO

Key Description Property Type
USLAB000086 ISS Station Mode 1=Standard | 2=Microgravity | 4=Reboost | 8=Proximity_Ops | 16=External_Ops | 32=Survival | 64=ASCR | 127=all_modes

SPARTAN/VVO

SPARTAN/VVO

Key Description Property Type
S0000001 Starboard Thermal Radiator Rotating Joint (TRRJ) Position (degrees) {0:f1}
S0000002 Port Thermal Radiator Rotating Joint (TRRJ) Position (degrees) {0:f1}
S0000003 Solar Alpha Rotary Joint (SARJ) Starboard Joint Angle Position (degrees) {0:f2}
S0000004 Solar Alpha Rotary Joint (SARJ) Port Joint Angle Position (degrees) {0:f2}

N/A

Key Description Property Type
TIME_000001 Greenwich Mean Time (GMT) %mT
TIME_000002 Year {0:d0}